Fer FALCON II Installation, Servicing & User Instructions page 5

Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

Technical Data
N.B. - The gas pressures at the burner and gas flows during the central heating phase given in the table refer to
nominal boiler output. To reduce this output (where necessary), gas pressure must be reduced until the required
output level is reached (see figures 4 and 5).
During
domestic hot water production, gas pressures to the burner must correspond to the maximum output
given in table for the type of gas.
Gas pressure must be adjusted during maximum draw-off of domestic hot water.
• Maximum working temperature for central heating flow: 85°C
• Maximum temperature of domestic hot water: 55°C, adjustable between 40°C and 55°C.
• Minimuum domestic cold water pressure required for 95% heat input:
- Flow restrictor fitted (standard) - 1,2 bar;
- Flow restrictor removed - 0,5 bar
FALCON II
5