Solaris OS Issues Fixed in Solaris 10 8/07 (Continued)
TABLE 12
CR ID
Description
6496337
The "cpumem-diagnosis" module may fail to
load after uncorrectable error(UE) panic.
Systems will function correctly but events
normally automatically diagnosed by FMA
using this module will require manual
diagnosis.
Example:
SUNW-MSG-ID: FMD-8000-2K, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Thu Feb 15 15:46:57 JST
2007
PLATFORM: SUNW,SPARC-Enterprise,
CSN: BE80601007, HOSTNAME: col2-ff-
em7-d0
6498283
Using the DR deleteboard(8) command
while psradm operations are running on a
domain might cause a system panic.
6499304
CPU isn't offlined and unexpected message is
displayed on console when many correctable
error(CE) occurs.
Example:
SUNW-MSG-ID: FMD-8000-11, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Fri Feb
2007
PLATFORM: SPARC-Enterprise, CSN:
BE80601035, HOSTNAME: FF2-35-0
Workaround
For Solaris 10 11/06, this has been fixed in
patch 125369-05.
[Workaround]
If problem occurred, implement the following
workaround:
1. Remove the following file.
2. Restart fmd service.
To avoid this problem in advance,
add "rm -f /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis" in
/lib/svc/method/svc-dumpadm file as
below.
For Solaris 10 11/06, this has been fixed in
patch 120011-07.
No workaround is available.
For Solaris 10 11/06, this has been fixed in
patch 125369-05.
[Workaround]
Check CPU status on XSCF.
2 18:31:07 JST
# rm /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
# svcadm restart fmd
#
# We haven't run savecore on a
dump device yet
#
savedev=none
rm -f /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
#