XCP Issues Fixed in Releases Earlier Than XCP 1092 (Continued)
TABLE 6
ID
Description
RTIF1-
After the XSCF reset or switching, you cannot
090427-002
login to XSCF using the LDAP server.
RTIF1-
After changed the SNMP configuration, when
090427-003
the XSCF switching occurred, the SNMP
function may be disabled.
RTIF1-
After you set https (using the self certificate
090430-001
authority) by XSCF and created a web server
certificate, https is not enabled.
RTIF1-
In a domain mounted with the 10 Gigabit
090508-001
Ethernet card (SE0X7HE1F), when you set the
OpenBoot PROM environmental variable
diag-switch? to true, the following
warning message appears on the console; and
at the same time, "Msg: Device error
(FCode informed error)" is recorded in
the error log.
WARNING: /pci@7,700000: FCODE map-
in doesn't match decoded register
type;
And when you execute the showstatus(8)
command, "Degraded" might be indicated to
the FRU which has installed the relevant card.
RTIF1-
When you use the sethttps(8) command to
090729-001
create a self-signed web server certificate, if
the number of characters specified in a
parameter exceeds 100, it might result in an
internal error and you might fail to create the
certificate.
RTIF1-
Once domain detected a failure related to
091109-001
DIMM or PCI, the error log about this detected
failure is registered every time you reset XSCF.
Workaround
No workaround is available.
Log in to active XSCF with initial account and
execute the following command to re-import
the certificate chain.
'setldap -c <remote file>'
No workaround is available.
In case this event occurred, the following
command may restore the function.
setsnmp disable
setsnmp disable (run "setsnmp disable"
twice)
setsnmp enable
To set the self certificate authority, do not
specify a blank character.
The entire output can be safely ignored.
To avoid these outputs, execute the following
command at the ok prompt and set the
OpenBoot PROM environmental variable
diag-switch? to false.
setenv diag-switch? false
Specify up to 100 characters in the parameter
and execute the sethttps(8) command again.
This error log can be safely ignored.