Fujitsu Sparc Enterpise M8000 Product Notes page 54

Hide thumbs Also See for Sparc Enterpise M8000:
Table of Contents

Advertisement

XCP Issues Fixed in Releases Earlier Than XCP 1092 (Continued)
TABLE 6
ID
Description
RTIF1-
The snmp daemon might quit.
071102-002
RTIF1-
Using the XSCF Web, when you selected COD,
071116-003
codusage details cannot be displayed correctly.
RTIF1-
When Internet Explorer 7 browser is used, the
071116-004
License key deletion cannot be executed on the
BUI COD page.
RTIF1-
While system power on, when the XSCF
071116-005
switching performed by switchscf(8)
command, PANIC might be generated in XSCF
before it switches, and "SHUTDOWN timeout"
may be stored in the error log.
RTIF1-
While XSCF is running, error message of
071116-006
"hang-up is detected" might be displayed
to XSCF console, and XSCF may reboot.
RTIF1-
If the following message is displayed on XSCF
071129-001
console, the XSCF might not start:
dbs[xxx]: ERR: scdb_init_all(): xx,
No space left on device
In addition, this error log might be be
registered:
XSCF process down detected
RTIF1-
When performing XSCF Shell commands
071129-002
remotely using SSH on the remote-control
device, the following messages might be
displayed:
stty: standard input: Invalid
argument
RTIF1-
An error log cannot be registered in XSCF
071129-003
when the following message is displayed on
Solaris OS by the I/O error:
SUNW-MSG-ID: SUN4-8000-4P, TYPE:
Fault
42
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1092 • April 2010
Workaround
To restart the snmp daemon, issue the
command setsnmp enable.
Use showcodusage(8) command to display
the codusage.
Use deletecodlicense(8) command to
delete a license key. Or use other browsers:
• Microsoft Internet Explorer 6.0
• Firefox 2.0 or later
• Netscape Navigator 7.1 or later
No workaround is available. This message can
be safely ignored.
Check that XSCF is started. If not started, use
the rebootxscf(8) command to restart XSCF,
or stop all the domains and then execute the
system power off/on (AC OFF/ON). To turn
on the system power that you turned off, wait
at least 30 seconds before power-on.
Replace the XSCF Unit.
None available at this time.
No workaround is available.