Fujitsu ASY9LSACW Service Manual page 92

Split type room air conditioner
Hide thumbs Also See for ASY9LSACW:
Table of Contents

Advertisement

SPE CI F I CA TI ON S
ELECTRICAL DATA
TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY
POWER SOURCE
FREQUENCY
RUNNING
CURRENT
INPUT WATTS
E.E.R.
COP
MOISTURE REMOVAL
AIR CIRCULATION
HIGH
MAXIMUM
CURRENT
FAN MOTOR
POWER SOURCE
INDOOR UNIT
Cooling
INDOOR UNIT
Heating
OUTDOOR UNIT Cooling
OUTDOOR UNIT Heating
NOISE LEVEL
INDOOR UNIT
Cooling
INDOOR UNIT
Heating
OUTDOOR UNIT Cooling
OUTDOOR UNIT Heating
2008.04.16
Cool & heat inverter
ASYA14LGC
AOYR14LGC
4.00 kW
5.00 kW
230 V
50 Hz
Cooling
4.9 A
Heating
5.7 A
Cooling
1.080 kW
Heating
1.295 kW
Cooling
3.70 kW/kW
Heating
3.86 kW/kW
2.1 L/h
800 m 3 /h
Cooling
800 m 3 /h
Heating
Cooling
9.0 A
Heating
10.5 A
230 V
High speed
1,500 r.p.m.
1,300 r.p.m.
Middle speed
Low speed
1,020 r.p.m.
Quiet
760 r.p.m.
1,500 r.p.m.
High speed
Middle speed
1,300 r.p.m.
Low speed
1,080 r.p.m.
Quiet
840 r.p.m.
870 r.p.m.
780 r.p.m.
High speed
44 dB
Middle speed
40 dB
Low speed
33 dB
Quiet
25 dB
High speed
44 dB
Middle speed
40 dB
Low speed
34 dB
Quiet
27 dB
48 dB
49 dB
DIMENSIONS
H x W x D
INDOOR UNIT
OUTDOOR UNIT
H x W x D
WEIGHT
INDOOR UNIT
Gross / Net
OUTDOOR UNIT
Gross / Net
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
DISCRIMINATION
WEIGHT (with oil)
STANDARD REFRIGERANT
REFRIGERANT TYPE
Pipe Length 15 m
FULL CHARGE
ADDITIONAL REFRIGERANT
MAXIMUM PIPING HEIGHT
1
260 x 790 x 198 mm
620 x 790 x 298 mm
10 kg / 7.5 kg
44 kg / 40 kg
Hermetic type,
4 pole, 3 phase,
DC inverter motor, Rotary
DA89X1C-20FZ
9.0 kg
1,000 g
R410A
1,000 g
20 m
1,100 g
20 g/m
15m