Download Print this page

Specifications - Bosch ISC-PPR1-W16G Installation Instructions Manual

Pir detector professional series

Advertisement

6.0 Specifications

Electrical
Power Requirements
Voltage (Operating): 9 VDC to 15 VDC
Current (Maximum): 15 mA. Current (Standby): 10 mA
Outputs
Relay: Solid state relay, normally-closed (NC) contacts
power supervised.
3 W, 125 mA, 25 VDC, resistance < 10 Ω.
Tamper: Normally-closed (NC) contacts (with cover on)
rated at 25 VDC, 125 mA maximum.
Connect tamper circuit to 24-hour protection circuit.
Trouble: Solid-state relay normally-closed (NC) contacts.
Mechanical
Enclosure Design
Color: White
Dimensions: 5.0 in. x 2.75 in. x 2.25 in.
(127 mm x 69 mm x 58 mm)
Material: High-impact ABS plastic
Indicators
Alarm Indicators:
• Blue LED for alarms
Detection Zones
Zones: 86
Frequency Information
Radio Frequency Interference (RFI) immunity:
No alarm or setup on critical frequencies in the range from
26 MHz to 1 GHz at 50 V/m.
Environmental
Relative Humidity: 0 to 95%, non-condensing
Temperature (Operating and Storage):
-20°F to +130°F (-29°C to +55°C)
For UL Certificated installations, +32°F to +120°F (0°C to
+49°C)
Environmental Class II EN 50130-5
Protection Rating: IP41, IK04 (EN 60529, EN 50102)
© 2009 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, NY 14450-9199 USA
(800) 289-0096
7/09
Page 6 of 6

Advertisement