1.0 General Information

The ISC-PPR1-W16x Professional Series PIR Detectors
are exceptionally suited for commercial indoor applications.
Sensor data fusion technology ensures that the detec-
tors send alarm conditions based on precise information.
Tri-focus optics eliminate coverage gaps and respond
efficiently to intruders. The powerful combination of unique
features in the Professional Series delivers superior catch
performance and virtually eliminates false alarms.
The self-locking two-piece enclosure, built-in bubble level,
flexible mounting height, and three optional mounting
brackets simplify installation and reduce service time.

2.0 Installation Procedure

Do Not:
Mount outdoors
Point toward windows
Install facing direct sunlight
Point towards fireplaces or air conditioners
Install near moving objects such as ceiling fans
The ISC-PPR1 is immune to small animals weighing less
than 10 lb. (4.5 kg). The small animal immunity feature was
not investigated by UL.
Mount the detector so that it is between 7 ft and 10 ft from
the floor (2.1 m - 3 m).
Mount the detector so that a person walks across the de-
tection pattern.
Typical mounting locations
2
�����������
��������������
1.1
Unlock and remove the cover
The cover lock snaps back to the locked position when the
cover is removed. The cover must be reattached with the
lock in the locked position.
2.2
Mounting Level
The detector has a built-in level which can be moved to
measure on two axes.