Certification Details; Scope Of Certification; Hazard - Navien NCM-1130HH Installation Instructions Manual

Gas fired waa mounted stirling engine m-chp
Table of Contents

Advertisement

1.2 Certification Details

This product is CE marked under the following regulations.
The product is certified to comply with the following requirements:
Directives
Directive 2009/142/EC
Directive 2006/95/EC
Directive 2004/108/EC
The following main standards are applied to achieve the directives
EN 483: 1999
EN 677: 1998
EN 60335-2-102: 2006
EN 55014-1: 2006
EN 61000-3-2:2006
EN 61000-3-3:2005
EN 55014-2: 2001

1.2.1 Scope of certification

Products Covered
Gas Categories
Gas Supply (G25)
Flue Types

1.3 Hazard

The appliance shall always be turned off by removing any heat demands.
Before working on the appliance ensures that the engine head temperature is below 150
is to prevent any uncontrolled engine start which would constitute a hazardous situation and/or
possible damage to the engine.
The engine head temperature can be found on the Fascia Controller, by following the procedure
below;
1. Press 'OK' button
2. Then press 'I' button (between 1 and 3 seconds)
3. Select 'Engineer Level' using the setting knob and press 'OK'
4. Select 'Input/Output test' and press 'OK'
5. Select 'Head Control Temperature' and read temperature from display and note value
6. Confirm head temperature by selecting 'Head Limit Temperature' and read temperature
from display and note value
7. Both readings should be within 50
Navien stirling engine m-CHP installation manual
The Gas Appliance Directive
The Low Voltage Directive
The Electromagnetic Compatibility Directive
Room sealed boilers < 70kW
Condensing boilers < 70kW
Safety of household electrical products
EMC emissions of household equipment
EMC limits for harmonic current emissions
EMC
limitation
fluctuations and flicker in public low-voltage supply
systems
EMC immunity of household equipment
NCM-1130HH 30kW
I
(G25) , I
(G20)
2L
2H
Requires a governed gas supply at 20 mbar inlet pressure for
I
(G20) and 25 mbar for I
2H
B23-B33-B53-C13-C33-C43-C53-C63-C83
°
C of each other
of
voltage
changes,
(G25)
2L
Page No:
voltage
°
C. This
7 of 88

Advertisement

Table of Contents
loading

Table of Contents