5.6.3.4 Selecting heating mode
Press the button to switch between the different operating modes. The
choice made is indicated by a bar which appears below the symbols.
Automatic operation
Automatic operation controls the room temperature according to the time program.
Characteristics of automatic operation:
Heating mode according to the time program
Temperature set points according to heating program "Comfort set point"
point"
Protective functions active
Automatic summer / winter changeover (ECO functions)
Continuous operation
Continuous operation maintains the room temperature at the selected operating level.
Heating to the Comfort set
point
Heating to the Reduced
set point
Characteristics of continuous operation:
Heating mode with no time program
•
Protective functions active
•
Automatic summer / winter changeover (ECO functions) and 24-hour heating limit inactive in
•
the case of continuous operation with Comfort set point
Protection
When using Protection, the heating system is off. But it remains protected against frost (frost
protection temperature), provided there is no power failure.
Characteristics of Protection:
Heating off
•
Temperature according to frost protection
•
Protective functions active
•
Automatic summer / winter changeover (ECO functions) and automatic 24-hour heating limit
•
active
Selecting DHW heating mode
The button is used to switch DHW heating mode on and off. The choice made is indicated by a bar
which appears below the symbols.
DHW mode
On
•
The DHW is heated according to the selected switching program.
Off
•
No DHW heating, the protective function is active.