Panasonic CS-E9PB4EA Service Manual page 70

Hide thumbs Also See for CS-E9PB4EA:
Table of Contents

Advertisement

Diagnosis
Abnormality /
display
Protection control
Outdoor cooling high
F95
pressure protection
Power transistor
F96
module overheating
protection
Compressor
F97
overheating
protection
Total running current
F98
protection
Outdoor direct
F99
current (DC) peak
detection
Abnormality
Protection
Judgment
Operation
4 times happen
within 20 minutes
4 times happen
within 30 minutes
3 times happen
within 30 minutes
3 times happen
within 20 minutes
Continuous
happen for 7 times
Problem
Cooling high pressure
protection
Power transistor module
overheat
Compressor overheat
Total current protection
Power transistor module
current protection
70
Check location
Check refrigeration system
Outdoor air circuit
PCB faulty
Outdoor air circuit (fan motor)
Insufficient refrigerant
Check refrigeration system
Power source or compressor
lock
Power transistor module faulty
or compressor lock

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-e9pb4eaCs-e12pb4eaCu-e12pb4ea

Table of Contents