11.2.6.1
Cutting and Flaring the Piping
1
Please cut using pipe cutter and then remove the burrs.
2
Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused.
Turn the piping end down to avoid the metal powder entering the pipe.
3
Please make flare after inserting the flare nut onto the copper pipes.
11.2.7
Disposal of Outdoor Unit Drain Water
If a drain elbow is used, the unit should be placed on a stand which is taller than 3 cm.
If the unit is used in an area where temperature falls below 0°C for 2 or 3 days in succession, it is recommended
not to use a drain elbow, for the drain water freezes and the fan will not rotate.
11.2.8
Auto Switch Operation
The following operations can be performed by
pressing the "AUTO" switch.
1
AUTO OPERATION MODE
The Auto operation will be activated
immediately once the Auto Switch is pressed.
2
TEST RUN OPERATION (FOR PUMP
DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the
Auto Switch is pressed continuously for more
than 5 sec. to below 8 sec. A "pep" sound will
occur at the fifth sec., in order to identify the
starting of Test Run operation.
11.2.9
Changing the Remote Control Transmission Code
1
Press AUTO SW continuously for more than
11 sec to below 16 sec, A "pep", "pep", "pep"
sound will occur at the eleventh sec.
2
Press the "A/C RESET" button once remote
control signal will activate the remote control
transmission code setting mode.
3
Press "OFF/ON" button. The new Remo-Con
No. will be accepted and memorized, after
which the new Remo-Con No. can be used.