Attached accessories
Applicable: Flaring piping kit CZ-52F
SELECT THE BEST LOCATION
INDOOR UNIT
• There should not be any heat source or steam near the
unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where air drainage can be easily done.
• A place
where
noise
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
• Indoor unit of this room air conditioner shall be installed
on the wall in a height of at least 2.5 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
• There should not be any animal or plant which could be
affected by hot discharged air.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short
circuit of the discharged air.
• If piping length is over 10 m, additional refrigerant
should be added as shown in the table.
prevention
is
taken into
Piping length and the elevation
Pipe size
Max.
Piping
Model
Gas Liquid
Length
A (m)
5/8"
1/4"
30
V28BKP5
Example:
If the unit will be installed at a 12 m distance, the quantity of
additional refrigerant should be 80 g...(12-10 m) × 40 g/m = 80g
Indoor/Outdoor unit installation diagram
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
43
CS-V28BKP5/CU-V28BKP5
Max.
Rated
Additional
Elevation
Refrigerant
Length Elevation
B (m)
(g/m)
25
7.5
5
40