Panasonic CS-V28BKP5 Service Manual page 4

Table of Contents

Advertisement

CS-V28BKP5/CU-V28BKP5
Indoor Unit
AUTO
OFF / ON
Auto Operation Switch
• Used when the remote control cannot be
used.
Remote Control Signal Receiving
Sound Control
• It can be controlled by pressing Auto
Operation Switch for 10 seconds.
TEST RUN
Operation Test Running / Pump
OFF / ON
Down Switch
• Used when test running or servicing.
Operation Indication Lamps (LED)
(Red)........ Lights up in operation,
POWER
(Orange).... Lights up in Sleep
SLEEP
(Orange).... Lights up in Timer
TIMER
Operation Mode
• Fan, Cooling, Soft Dry, and Automatic
Mode.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
blinks in Automatic
Operation Mode judging
Mode Operation.
Setting.
Auto Restart Control
• Operation is restarted after power failure
at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates at Lo fan speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Fan : Fan speed varies Low and stop in
accordance with the differential of the
indoor temperature & set temperature.
– Cooling : Fan rotates at Hi and Me
– Soft Dry: Fan rotates at SLo speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
4
speed. Deodorizing control
is available.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-v28bkp5

Table of Contents