Curtis WB-10-12 Service Manual

10 gallon

Advertisement

Quick Links

MODELS INCLUDED
• WB-10-12
CAUTION: Please
use this setup
procedure before
attempting to use this
appliance. Failure to follow
the instructions can result in
injury or the voiding of the
warranty.
CAUTION: DO NOT
connect this unit
to hot water. The
inlet valve is not rated for hot
water.
WARNING: DO NOT
place this water
boiler closer than
six [6] inches from
wall. Unit must have adequate
cross-ventilation.
WARNING HOT
LIQUID, Scalding
may occur. Avoid
splashing.
C
ISO 9001:2008
WILBUR CURTIS COMPANY
Montebello, CA 90640
W
ilbur
Water Boiler, 10 Gallon – Service Manual
Important Safeguards/Conventions
This appliance is designed for commercial use. Any servicing other than
cleaning and maintenance should be performed by an authorized Wilbur
Curtis Company service technician.
• Do Not immerse the unit in water or any other liquid.
• To reduce the risk of fire or electric shock, do not open side or bottom
panel. No user serviceable parts inside.
• Keep hands and other items away from hot parts of unit during
operation.
• Never clean with scouring powders, bleach or harsh chemicals.
Symbols:
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
The Curtis Water Boiler is Factory Pre-Set and Ready to Go... Right from the Carton.
Factory Settings:
• Water Temperature = 200°F
System Requirements
• Water Source: 20 – 100PSI (Min Flow Rate of 1 GPM)
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can
be moved for cleaning underneath.
2. This equipment is to be installed with adequate backflow protection to comply with applicable federal,
state and local codes..
3. Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed
and maintained in accordance with federal, state, and local codes.
SETUP STEPS
1. Place unit at counter height. on a firm, level base, in such a way that it can be connected to water and power supply.
2. Install the supplied water faucet on the faucet shank in front of the unit.
3. Connect water line to inlet fitting on valve. It is recommended that some type of water mineral reducing filter be used
in the water line before entering the unit. Water pressure entering boiler is must be stable and provide minimum of
1 gallon per minute. Use water regulator for constant pressure. Required water pressures, 20 to 100 psi. Turn on
water valve.
5. Hook-up power to the unit (refer to schematic for power requirements).
6. Turn on the circuit running power to unit. The water inlet valve will open, filling the unit. When the boiler has filled,
turn on boiler at the thermostat, twisting the knob clockwise.
7. Heating tank will require 50 to 60 minutes to attain operating temperature. Thermostat indicator will light at this time.
FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM
C
C
urtis
ompany
• Volume = 10 Gallons
• Electrical: See electrical schematic.
, i
.
nC

Advertisement

loading

Summary of Contents for Curtis WB-10-12

  • Page 1 Sanitation Requirements the instructions can result in injury or the voiding of the warranty. The Curtis Water Boiler is Factory Pre-Set and Ready to Go… Right from the Carton. Factory Settings: • Water Temperature = 200°F • Volume = 10 Gallons...
  • Page 2: Illustrated Parts List

    Illustrated Parts List...
  • Page 3: Parts List

    LABEL, “HOT WATER” (WB-10) WC-2966 FITTING, WATER INLET WB-10 WC-5386 TUBING ASSEMBLY, WATER INLET WC- 922-04 ELEMENT, HEATING 3.5KW 220V W/NUTS & WSHRS WC-37136 KIT, THERMOSTAT WB-10-12 WC-3220 BEZEL, THERMOSTAT ELECTRIC WC-3217 KNOB, ELECTRIC THERMOSTAT WC- 608 LEVEL CONTROL, WATER 120V WC-5611...
  • Page 4: Troubleshooting

    TROUBLE SHOOTING PROBLEM: WATER WILL NOT REFILL SOLUTION POSSIBLE CAUSE 1. Water line closed or Check the water system at your facility to make sure the line is open. Replace the water clogged filter filter. 2. Valve coil burned out Turn machine off.
  • Page 5 TROUBLE SHOOTING CONTINUED: PROBLEM: WATER DOES NOT REACH PROPER TEMPERATURE SOLUTION POSSIBLE CAUSE 2. Defective thermostat Replace thermostat if contacts are open when knob is fully clockwise and water tem- perature is less than 190º F. You will measure 120 volts (approximately) to ground from both thermostat terminals when it is ON and from only one terminal when it is OFF.
  • Page 6 ELECTRICAL SCHEMATIC 220V INLET...
  • Page 7 This page intentionally left blank.
  • Page 8: Product Warranty Information

    This includes institutional and correctional facilities. The Wilbur Curtis Company will allow up to 100 miles, round trip, per in-warranty service call.