Star 8124RCB Installation And Operating Instrictions

Ultra-max gas radiant charbroiler and ultra-max gas lava rock charbroiler

Advertisement

ULTRA-MAX GAS RADIANT CHARBROILER
ULTRA-MAX GAS LAVA ROCK CHARBROILER
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death.
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY:
gasoline or other flammable vapors or liquids
in the vicinity of this or any other appliance.
Star
Manufacturing
International Inc.
0 Sunnen Drive
St. Louis, MO 6343
Phone: (34) 678-6303
Fax: (34) 78-274
8124RCB, 8136RCB,
8148RCB, 8160RCB, and 8172RCB
8024CB, 8036CB,
8048CB, 8060CB, and 8072CB
Do not store or use
MODELS
MODELS
WARNING:
in accordance with current regulations and
Read
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local
gas supplier.

Installation
and
Operating
Instructions
2M-Z7906 Rev. B 8/25/
This appliance shall be installed

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8124RCB and is the answer not in the manual?

Questions and answers

Summary of Contents for Star 8124RCB

  • Page 1 Instructions St. Louis, MO 6343 Phone: (34) 678-6303 Fax: (34) 78-274 2M-Z7906 Rev. B 8/25/ ULTRA-MAX GAS RADIANT CHARBROILER MODELS 8124RCB, 8136RCB, 8148RCB, 8160RCB, and 8172RCB ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CB, 8036CB, 8048CB, 8060CB, and 8072CB WARNING: WARNING:...
  • Page 2: Safety Symbol

    RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability. Star reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
  • Page 3: Specifications

    SPECIFICATIONS 8124RCB - Radiant, 8024CB - Lava Rock Type: Manual Control 4 Controls, 80,000 BTUH (20,000 BTUH Nat/LP per burner) 603 sq. in. (3,890 sq. cm) Grid Area Approximate Weight: Installed - 74 Lb s (78.9 kg), shipping - 240 Lbs (08.9 kg) Dimensions: 24"...
  • Page 4: General Installation Data

    GENERAL INSTALLATION DATA CAUTION This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home CAUTION nor for use directly by the general public in food service locations. The Ultra-Max™...
  • Page 5 LEVELING UNIT This charbroiler is supplied with 4 feet or floor stand legs which must be screwed into the body. Unit must CAUTION be level. Level unit by adjusting the (4) feet which DO NOT INSTALL WITHOUT ATTACHING FEET have an adjustment of -3/4" for accurate and perfect OR SUPPLIED STAND LEGS AND SHELF - DO line-up with other units.
  • Page 6 GENERAL INSTALLATION DATA (continued) PLACING RADIANTS - RCB SERIES After the unit is unpacked and installed, place  radiant above each burner. Install each radiant on 2 slots of the rear wall and on  pin of the front wall of the liner weld assembly. Refer to the exploded view in this manual for orientation of the radiants.
  • Page 7 PILOT LIGHTING INSTRUCTIONS The charbroiler is equipped with standing pilots, and should be lit immediately after the gas is turned on. . Turn off main valve to unit. 2. Turn off all knobs and pilot valves and wait 5 minutes to clear gas. 3.
  • Page 8: Shutting Down Instructions

    CAUTION CHARBROILERS ARE HOT! NEVER ATTEMPT TO CHANGE THE GRATE CAUTION POSITION WHILE FOOD PRODUCTS ARE COOKING. FLARE UPS CAN OCCUR UNEXPECTEDLY. TURN OFF CHARBROILER, AND ALLOW THE CHARBROILER TO COOL. SHUTTING DOWN INSTRUCTIONS Turn the burner valve knobs to the off position to turn burners off and close manual valve gas shutoff.
  • Page 9 LIMITED EQUIPMENT WARRANTY All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies.
  • Page 10 USED ONLY ON 48", 60" & 72" MODELS 8124RCB, 8024CB SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE 8136RCB 8148RCB STAR MANUFACTURING INTERNATIONAL, INC. MODEL: 8160RCB 8172RCB SK1865 REV. C 5/9/06 8036CB 8048CB...
  • Page 11: Parts List

    8024 / 8036 / 8048 / 8060 / 8072 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER Some items are included for illustrative purposes only and in certain instances may not be available. Star Manufacturing International, Inc.

Table of Contents