Star 8124RCBB Installation And Operating Instructions Manual

Ultra-max gas radiant charbroiler. ultra-max gas lava rock charbroiler

Advertisement

Available languages

Available languages

Quick Links

ULTRA-MAX GAS RADIANT CHARBROILER
8148RCBB, 8160RCBB, and 8172RCBB
ULTRA-MAX GAS LAVA ROCK CHARBROILER
8048CBB, 8060CBB, and 8072CBB
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death.
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY:
gasoline or other flammable vapors or liquids
in the vicinity of this or any other appliance.
Star
Manufacturing
International Inc.
10 Sunnen Drive
St. Louis, MO 63143
Phone: (314) 678-6303
Fax: (314) 781-2714
MODELS
8124RCBB, 8136RCBB,
MODELS
8024CBB, 8036CBB,
Read
Do not store or use
2M-Z20327 Rev. B
WARNING:
This appliance shall be installed
in accordance with current regulations and
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local
gas supplier.
Installation
and
Operating
Instructions
11/30/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8124RCBB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Star 8124RCBB

  • Page 1 Instructions St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 2M-Z20327 Rev. B 11/30/15 ULTRA-MAX GAS RADIANT CHARBROILER MODELS 8124RCBB, 8136RCBB, 8148RCBB, 8160RCBB, and 8172RCBB ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB WARNING: WARNING:...
  • Page 2: Safety Symbol

    RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability. Star reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
  • Page 3: Specifications

    Grid Area Controls Installed Shipped Width Depth Height RADIANT 603 sq in 196 lbs 262 lbs 24” 8124RCBB 80,000 (3,890 sq cm) (88.9 kg) (118.9 kg) (61 cm) 906 sq in 273 lbs 349 lbs 36” 8136RCBB 120,000 (5,845 sq cm) (123.8 kg)
  • Page 4: General Installation Data

    GENERAL INSTALLATION DATA This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. CAUTION The Ultra-Max™...
  • Page 5: Floor Stand Model

    LEVELING UNIT CAUTION This charbroiler is supplied with 4 feet or floor stand legs which must be screwed into the body. Unit must be DO NOT INSTALL WITHOUT ATTACHING FEET level. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4"...
  • Page 6: Pilot Lighting Instructions

    GENERAL INSTALLATION DATA (continued) PLACING RADIANTS - RCBB SERIES After the unit is unpacked and installed, place 1 radiant above each burner. Install each radiant on 2 slots of the rear wall and on 1 pin of the front wall of the liner weld assembly. Refer to the exploded view in this manual for orientation of the radiants.
  • Page 7: Burner Operation

    4. Turn on main valve and light all pilots. 5. Adjust pilot light flames as small as possible, usually about 1/2" high, but high enough to light burner immediately when burner valve is turned on high. 6. Turn burner knobs to desired setting. 7.
  • Page 8 Replace with PS-Z20939 Current Burner Design SOME ITEMS ARE INCLUDED FOR 8124RCBB, 8024CBB ILLUSTRATIVE PURPOSES ONLY AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE MODEL: 8124RCBB, 8136RCBB, 8148RCBB 8160RCBB, 8172RCBB STAR MANUFACTURING INTERNATIONAL, INC. 8024CBB, 8036CBB, 8048CBB SK2895 Rev. D 12/02/15...
  • Page 9: Parts List

    November 30, 2015, Rev B 8024/8036/8048/8060/8072 Ultra-Max Lava Rock Gas Charbroiler Model: Ultra-Max Charbroiler Radiant & Lava Rock Fig No. Part Number Quantity Description Application 8124RCBB, 8024CBB 8136RCBB, 8036CBB 2F-Z4692 GRATE CHARBROILER 8148RCBB, 8048CBB 8160RCBB, 8060CBB 8172RCBB, 8072CBB 8124RCBB 8136RCBB...
  • Page 10 Application 8124CBB, 8024CBB 8136RCBB, 8036CBB 2M-Z15245 DIAL GRAPHIC, MANUAL UM 8148RCBB, 8048CBB 8160RCBB, 8060CBB 8172RCBB, 8072CBB H5-Z15939 FRONT PANEL 24” 8124RCBB, 8024CBB H5-Z15943 FRONT PANEL 36” 8136RCBB, 8036CBB H5-Z15284 FRONT PANEL 48” 8148RCBB, 8048CBB H5-Z15926 FRONT PANEL 60” 8160RCBB, 8060CBB H5-Z15935 FRONT PANEL 72”...
  • Page 11 8160RCBB, 8060CBB 8172RCBB, 8072CBB 8124CBB, 8024CBB 8136RCBB, 8036CBB 2V-Z17948 PILOT TUBE 8148RCBB, 8048CBB 8160RCBB, 8060CBB 8172RCBB, 8072CBB 8124RCBB, 8024CBB 8136RCBB, 8036CBB 2F-Z17447 BURNER ASSY UM CHAR 8148RCBB, 8048CBB 8160RCBB, 8060CBB 8172RCBB, 8072CBB PS-Z20939 OLDER BURNER & ORFICE CONV. KIT UNITS WITH OLDER BURNERS...
  • Page 12 LIMITED EQUIPMENT WARRANTY All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies.
  • Page 14 INSTRUCTIONS POUR ÉTEINDRE LE BARBECUE Pour éteindre les brûleurs, tourner les boutons des brûleurs sur la position de fermeture. NETTOYAGE Nettoyer le barbecue régulièrement. Enlever la section du grille et la laver dans l’évier. Enlever à la brosse les particules carbonisées. Enlever et laver le bac à eau. Nettoyer les surfaces extérieures à l’aide d’un chiffon et d’un détergent.
  • Page 15: Instructions De Fonctionnement

    INSTRUCTIONS CONCERNANT LES VEILLEUSES D’ALLUMAGE Le barbecue est équipé de veilleuses stationnaires et il faut l’allumer dès que le bouton de gaz est ouvert. 1. Éteignez la principale valve à unité. 2. Éteignez tous les boutons et valves du pilote et attendez 5 minutes éclaircir du gaz.
  • Page 16 PLAÇANT RADIANTS - RCBB SÉRIE Après que l'unité soit déballée et est installée, placez-en 1 radiant au-dessus de chaque brûleur. Installez chaque radiant sur 2 fentes du mur arrière et sur 1 épingle du mur de devant de l'assemblée de la soudure du paquebot.
  • Page 17 ÉQUILIBRAGE DE L’APPAREIL Ce charbroiler est assuré avec 4 pieds ou jambes de MISE EN stand de plancher qui doivent être vissés dans le corps. GARDE L'unité doit être niveau. Équilibrer l’appareil en ajustant N’INSTALLEZ PAS SANS ATTACHER ES les (4) pieds qui ont un réglage de 1-3/4 po., en vue d’un PIEDS OU DES JAMBES ET L'ETAGERE alignement exact et parfait avec d’autres appareils.
  • Page 18 DONNÉES GÉNÉRALES D’INSTALLATION Cet équipement n’est conçu et vendu que pour l’utilisation commerciale par le personnel formé et sachant l’utiliser et il n’est pas vendu pour l’utilisation à la maison, ni pour l’usage du public dans les endroits de pique-nique. MISE EN Le barbecue de la série Ultra-Max est équipé...
  • Page 19: Entretien Et Réparations

    L’utilisation de toute pièce autre que les pièces d’origine STAR dégage le fab- ricant de toute responsabilité. Star se réserve le droit de changer les spécifications et la conception du produit sans préavis. Ces changements ne donnent pas le droit à l’acheteur d’obtenir les changements, améliorations, ajouts ou remplacements correspondants pour...
  • Page 20 St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 2M-Z20327 Rev. B 11/30/2015 BARBECUE A GAZ RAYONNANT ULTRA-MAX MODELES 8124RCBB, 8136RCBB 8148RCBB, 8160RCBB, et 8172RCBB BARBECUE A GAZ ROCHE DE LAVE ULTRA-MAX MODELES 8024CBB, 8036CBB, 8048CBB, 8060CBB, et 8072CBB AVERTISSEMENT: L’installation inexacte,...

Table of Contents