Menu Settings Variometer; Digital-Vario Integrator; Threshold Value Last Thermal; Basic Filter (Turbulence Filter) - Brauniger IQ-MOTOR-eco Operation Manual

Table of Contents

Advertisement

2.2.4

Menu Settings Variometer

Tip: By use of the PC Software Flychart Extras -> Flight instrument Options, all instrument
characteristics can be set easily and comfortably.
By use of the feature tone simulation the adjusted values can be checked easily!

2.2.4.1 Digital-Vario Integrator

Main Setup Menu
Setting of average value time constant from 1 – 30 seconds for the digital Variometer display.

2.2.4.2 Threshold value last thermal

Main Setup Menu
Threshold for the display arrowhead of last thermal, the range can be set between 0,5 up to 3 m/s.
The thermal arrowhead in the compass rose points to the direction, where the integrated Vario was
the last time higher than this threshold value.

2.2.4.3 Basic filter (Turbulence filter)

Main Setup Menu
The response characteristics of Variometer display and of climb- or sink acoustics can be adapted
within a wide range in accordance to the pilot's needs or the weather conditions.
In order to simplify the settings, Flytec has defined 4 basic- resp. turbulence filters.
Variometer - sensitivity / response characteristics
Filter No.
0
weak filtering
1 Default
normal filtering
2
high filtering
3
very high turbulence filtering
2.2.5

Variometer - Acoustic settings

The climb tone is a frequency modulated beep tone whose pitch and beep tone sequence rises
rhythmically at increasing climb rate. The pulse/pause ratio is 1:1.
Following settings are possible under Main Setup Menu
Variometer Sink Acoustic:
Climb Acoustic settings:
Climb threshold:
Basic frequency
Frequency change
Pitch modification
Pitch mode
Pre-Thermal Threshold: = trigger point of Pre-Therm.acoustic
Sink Acoustic settings:
Sink threshold:
Basic frequency
Sink Alarm
Operation Manual IQ-MOTOR-eco GPS
Variometer
Digital
Variometer
Variometer
Filter .
= climb acoustic threshold
= basic tone pitch Vario climb
= increase of tone pitch
(frequency modification per m/s)
= increase of beep interval per m/s
= linear or exponential
increase of climb acoustic
=Sink tone threshold
=basic tone pitch Vario sink
=Sink alarm threshold
for very calm air in Winter
for enjoyment thermal with light turbulence
thermal with turbulence
for very rough and strong thermal
Variometer Climb Acoustic and
0
m/s
15
Climb tone
Climb accou.
threshokd
Pre Thermal
threshold
Soundloss
range
Sinktone
threshold
Sink
tonealarm

Advertisement

Table of Contents
loading

Table of Contents