Section 6: Troubleshooting; Basic Troubleshooting-Power Source Faults - Thermal Arc 181i FABRICATOR Service Manual

Multi process welding inverter
Hide thumbs Also See for 181i FABRICATOR:
Table of Contents

Advertisement

TROUBLESHOOTING

6.01 Basic Troubleshooting-Power Source Faults

The following table is a guide for analysing problems and making repairs to the Power Source.
Fault
1
There is no weld
output and all front
panel displays are off
2
There is no weld
output and all front
panel displays are off
or flickering on & off
3
There is no weld
output and the yellow
over temperature light
is on
4
Mode switch does not
change welding mode
5
The wirefeed motor
and the weld output
do not operate when
the torch trigger
switch is depressed
6
The wirefeed motor
does not operate
when the torch trigger
switch is depressed
7
The wirefeed motor
operates at maximum
speed and cannot be
adjusted.
Manual 0-5152
SECTION 6:
TROUBLESHOOTING
Possible Cause
A
The main Power Switch is set to OFF
B
Line fuse is blown
C
The main Power Switch is faulty
D
Loose connection to EMC board
E
Faulty Power Inverter board
F
Faulty Control board
G
Faulty Display board
A The internal protection circuit to shut
the unit down if the mains supply
voltage is too high has operated
A
Unit has overheated
B
Airflow inlet or outlet ducts are
blocked
C
Fan does not operate
A Faulty Display board
A
Internal wiring fault
B
Over temperature light is on
C
Power Source set to REMOTE
D
Trigger wires shorted to weld voltage
inside torch
E
Trigger wires or torch switch faulty
F
Faulty Power Inverter board
G
Faulty Control board
H
Faulty Display board
A
Power Source set to TIG or STICK
mode
B
Wirefeeder motor wiring has become
loose
C
Trigger wires or torch switch faulty
D
Faulty Power Inverter board
A
Faulty Power Inverter board
B
Faulty Display board
Table 6-1 Power Source Faults
A
Set main Power Switch to ON
B
Replace Line fuse
C
Replace main Power Switch
D
Tighten connections
E
Replace Power Inverter board
F
Replace Control board
G
Replace Display board
A
Check to see if mains supply
voltage is <274VAC. A
generator with poor voltage
regulation may cause a supply
voltage in excess of 274VAC.
Connect Power Source to a
supply voltage <274VAC.
A
Allow unit to cool with fan
running until over temperature
light extinguishes
B
Remove blockages from
airflow ducts
C
Replace fan. Check fan wiring
header is plugged securely
into Control board. Check fan
wiring is not damaged
A
Replace Display board
A
Check continuity of internal
wiring from Torch adaptor
through to boards
B
Allow unit to cool
C
Set switch to LOCAL
D
Repair trigger wires in torch
E
Check & Repair
F
Replace Power Inverter board
G
Replace Control board
H
Replace Display board
A
Set power Source to MIG mode
Check motor wiring
B
Check & Repair
C
Replace Power Inverter board
D
A
Replace Power Inverter board
B
Replace Display board
6-1
FABRICATOR 181i
Remedy
Troubleshooting