External Adjustment - Nibe F470 User Manual

Exhaust air heat pump
Hide thumbs Also See for F470:
Table of Contents

Advertisement

5.
Press the OK button to exit the setting.
To read off a heating curve:
1.
Turn the control knob so that the ring on the shaft with the outdoor
temperature is marked.
2.
Press the OK button.
3.
Follow the grey line up to the heat curve and out to the left to read off
the value for the supply temperature at the selected outdoor temperature.
4.
You can now select to take read outs for different outdoor temperatures
by turning the control knob to the right or left and read off the corres-
ponding flow temperature.
5.
Press the OK or Back button to exit read off mode.
TIP
Wait 24 hours before making a new setting, so that the room temperature
has time to stabilise.
If it is cold outdoors and the room temperature is too low, increase the curve
slope by one increment.
If it is cold outdoors and the room temperature is too high, lower the curve
slope by one increment.
If it is warm outdoors and the room temperature is too low, increase the
curve offset by one increment.
If it is warm outdoors and the room temperature is too high, lower the curve
offset by one increment.

external adjustment

Menu
1.9.2
climate system
Setting range: -10 to +10 or desired
room temperature if the room sensor
is installed.
Default value: 0