Installation Instructions - Ariston A45V Use And Care & Installation Instructions Manual

Tumble dryer
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions

Read these instructions with care.
These instructions are provided for use by qualified installers, in addition, the installation
must comply with:
In the United States, in accordance with the National Electric Code
ANSI/NFPA70 - latest edition and any State, Municipal or local codes.
In Canada, in accordance with the Canadian Electric Code C22.1 - latest
edition and any Provincial, Municipal or local codes.
Electrical
The dryer comes with a four-cord power supply cord fitted with a 14-30P (plug). A
receptacle should be installed in a location accessible after the dryer in installed.
If the dryer is installed in a mobile home or in certain areas where local codes do not allow
grounding of the Neutral, the four-wire dryer cord assembly fitted must be used.
If a 10-30R (receptacle) is installed, a locally obtained 3-wire dryer cord kit rated 240V
min, 30A and marked for clothes dryers, should be fitted.
To fit a 10-30P dryer cord assembly follow the following procedure:
Make sure the dryer is not plugged into a power outlet.
Remove the cover from the cable junction box located on the rear of the
dryer.
Loosen the nut securing the cable bushing, disconnect and discard the
existing cable and bushing.
Prepare the ends of the new cable, removing any lugs that may be fitted,
strip the insulation to fit the terminal block.
Follow any instructions provided with the kit and fit the cable using the
strain relief supplied with the kit. Do not fully tighten the strain relief at
this stage.
Link the Neutral and Ground terminals, by removing one end of the
Green link wire fitted to the ground (
Neutral terminal (N).
Connect the ground wire (Green) and the L1 and L2 wires.
On flat cords the center wire is the Neutral conductor, fit to the terminal
marked 'N'. Fully tighten the terminal block screws and position the cord,
finally fully tighten the strain relief.
Refit the cover to the box.
Grounding
Some local codes may require a separate ground. In such cases the
required ground wire, clamp and screw must be purchased separately.
NEVER ground the dryer to plastic plumbing lines, gas lines or water pipes.
NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE CONSULT A
QUALIFIED ELECTRICIAN.
) terminal and fitting it to the
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents