Clearances - Rinnai ORH15S Operation & Installation Manual

Outdoor radiant heater
Table of Contents

Advertisement

CLEARANCES

Minimum clearances when mounting the heater on A VERTICAL WALL.
220 Min.
100 Min.
Minimum clearances when mounting the heater parallel with A CEILING.
600 Min
Minimum clearances when mounting the heater at an ANGLE TO A CEILING.
600 Min.
Rinnai
1500 Min.
1000 Min. to surfaces (ie table tops, ect)
2100 Min. from floor
3000 Max. from floor (recommended)
175 Min
600 Min
1000 Min. to surfaces (ie table tops, ect)
2100 Min. from floor
3000 Max. from floor (recommended)
125 Min.
1500 Min.
1000 Min. to surfaces (ie table tops, ect)
2100 Min. from floor
3000 Max. from floor (recommended)
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
9
INSTALLATION
600 Min.
Same both ends
600 Min.
Same both ends
600 Min.
Same both ends
ORH OIM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Orh24lOrh18mOrh32xl

Table of Contents