Connection To The Mains Supply; This Appliance Must Be Earthed; Non-Rewireable Mains Plug - Apelson UBWC300B Instruction Manual

Apelson ubwc300b built-in wine cooler
Table of Contents

Advertisement

Connection to the Mains
Supply
Check that the voltage marked on the product
corresponds with your supply voltage.
This product is fitted with a 13A plug complying with
BS1363. If this plug is unsuitable or needs to be
replaced, please note the following:
WARNING:

THIS APPLIANCE MUST BE EARTHED.

Important: The wires in the mains lead are coloured
in accordance with the following code:
GREEN/YELLOW - EARTH
BLUE - NEUTRAL
BROWN - LIVE
Earth
(Green/Yellow)
Neutral
(Blue)
This appliance is equipped with a plug fitted with a
13 amp fuse. Should the fuse fail, then it must be
replaced with an ASTA approved fuse (conforming
to BS1362) of the same rating. If you need to
replace the plug or if the plug is of the incorrect type
for your socket, remove it and replace it with an
appropriate type. Dispose of the old plug safely.
As the colors of the wires in the mains lead of this
appliance may not correspond with the colored
markings identifying the terminals in your plug,
proceed as follows: The GREEN/YELLOW wire is
the EARTH and must be connected to the terminal
which is marked with the letter 'E' or by the earth
symbol
or colored GREEN or
GREEN/YELLOW.
Live
(Brown)
The BLUE wire is the NEUTRAL and must be
connected to the terminal which is marked with the
letter 'N' or colored BLACK.
The BROWN wire is the LIVE wire and must be
connected to the terminal which is marked with the
Letter 'L' or colored RED.
Always ensure that the plug cord grip is fastened
correctly.
If in doubt consult a qualified electrician who will be
pleased to do this for you. This product conforms to
EC Directive 92/31 /EEC with respect to
Electromagnetic Compatibility.

NON-REWIREABLE MAINS PLUG

If your appliance is supplied with a nonrewireable
plug fitted to the mains lead, you will find that it
incorporates a fuse, the value of which is indicated
either on the base of the plug or on the fuse carrier.
Should the fuse need replacing, you must use an
ASTA approved one (conforming to BS1362) of the
same rating.
If the fuse cover is lost, the plug must not be used
until a replacement is obtained from an electrical
supplier.
If you need to remove the plug, cut it from the mains
lead and immediately dispose of it. Never attempt to
re-use this plug or insert it into a socket outlet as
there is a very great risk of an electric shock.