Programming for the Alpha Pager Module

In field 2*30, enter 1 to enable the Alpha Pager
Module.
Program fields 2*31 – 2*88 for the paging service
parameters (see the Programming Guide). The
events (e.g., field 2*39) must be programmed
for the pager to work.
If you have a printer connected to the module,
program field 1*69 with a 0 for a parallel printer or
a 1 for a serial printer.
Additionally, fields 05 and 14 may be programmed
when using the Alpha Pager Module.
Fields for programming the delay times (e.g.
2*36 and 2*37 for pager 1) are relevant only
when using numeric format for the pager.

Programming for Access Control

VistaKey
See the VistaKey-SK Installation and Setup Guide for
the detailed programming instructions.
VistaKey Dialer Enables
When the VistaKey is installed with an alarm system,
the system defaults are set so that the system does not
send reports to the central station. The programming is
accomplished in field 1∗35 for the following events:
ACS Troubles - To enable or disable ACS trouble
reporting.
ACS Bypasses - To enable or disable ACS bypass
reporting.
ACS System - To enable or disable ACS system
reporting, (i.e., ACS module reset).
ACS Alarms - To enable or disable ACS alarm
reporting.
Dialer (Trace) - To enable or disable access
grant/denial events sent to the central station.
The PassPoint ACS can dedicate some of its inputs for
use as regular VISTA-128BP/VISTA-250BP hardwired
zones (the zone response type is ACS). The PassPoint
ACS can also utilize the control panel dialer for reports
to the central station.
Using ACS Zone Inputs
If the PassPoint ACS has uncommitted zones, these
may be used by the VISTA-128BP/VISTA-250BP as
hardwired zones. To program for ACS zone inputs,
perform the following steps:
Step
Action
1
Enter Zone Programming in the #93 Menu
Mode.
2
Program this zone as any other zone. Indicate
the input type as ACS (10).
3
Enter the PassPoint ACS's zone ID (00-31)
See Zone Programming in the Programming Guide for a
detailed explanation.

Programming for TeleSmart

The TeleSmart module has a fixed address of 24 (it
cannot be changed). Set Device Address 24 in the
VISTA-128BP/VISTA-250BP Device Programming
mode for Device Type 11, TeleSmart. Also, Device
Address 23 must be set for Device Type 01, Alpha
Console, but do not actually connect a device to
the control panel set to that address. This must be
done so that TeleSmart can be accessed remotely (off
premises).
Refer to Device Programming in the #93 Menu Mode in
the VISTA-128BP/VISTA-250BP Programming Guide
for specific instructions.
PassPoint Dialer Events
All PassPoint ACS events can be sent to the VISTA-
128BP/VISTA-250BP dialer via the VGM. These events
will also be logged into the control's event log. This is
enabled in the PassPoint ACS. See the PassPoint ACS
documentation for a detailed explanation.
Programming the VISTA Gateway Module
See the PassPoint ACS instructions to program the
VISTA Gateway Module.
Access Control of an Entry/Exit Point Using
VistaKey or PassPoint
The control can send entry and exit requests to the
VistaKey or PassPoint ACS utilizing keypads and
button-type (BR) RF transmitters. A zone is
programmed with a response type 27 (Access Point) and
an appropriate input type (console, RF).
Using the Alpha Keypad
Step
Action
1
Enter Zone Programming in the #93 Menu
Mode.
2
Program the zone with a response type 27
(Access Point).
3
Enter the access point number (00-31) of the
door.
4
Program whether this is an entry or exit point.
5
Enter the partition number.
6
Enter the input type as CS (09).
7
Enter the keypad ECP address.
See Zone Programming in the Programming Guide for a
detailed explanation.
Section 4 – Programming
4-9