SPECIFICATIONS - Room Sensor [RBT-3C and RBH-3C]
Case dimensions
Case material
Case ingress protection
Case electrical protection
Radio frequency band
Operating range
Power source
Temperature accuracy - typical [RBT-3C]
Temperature accuracy - typical [RBH-3C]
Humidity accuracy - typical [RBH-3C]
Latching relay voltage rating
Maximum Switching Current
Latching relay contacts rating - Resistive Load
Latching relay contacts rating - Inductive Load
Operating temperature range
Storage temperature range
Relative humidity
© 2 Save Energy Limited 2013
86mm x 86mm x 37mm
Thermoplastic, flame retardant
IP30
Double Insulated
868MHz unlicenced ISM band
Up to 50m (in free space)
2 x 1.5V Alkaline AAA batteries
±0.5°C
±0.2°C
±1.8%RH
230V a.c. ±10% 50/60Hz
8A
8A @250V a.c. power factor Ø1
3.5A @250V a.c. power factor Ø0.4
0°C to +40°C
-25°C to +65°C
25% to 95% non-condensing