Align the two modules to be joined so that the top of the lower one and the bottom of the upper one are close to one
another, say 4" (10 cm) apart.
On "master & slave" systems Insert the free end of the short ribbon cable into the socket on the second module. Using a
small Phillips screw driver, secure the connector with two 4-40 Phillips head screws (supplied). Make sure the connectors
are fully seated. If necessary, use a flashlight to check because if the connectors are not seated properly, you may have to
disassemble the column in order to seat them correctly. Do not connect this cable on "all master" systems.
Align the two modules and slide them together, making sure the holes in the heavy joining plates align with the holes in the
modules. Install the remaining screws into the joining plates and tighten all the screws. The assembly is now complete.
If you are making a triple array, repeat the procedure to join the ICL-FR-LM module to the other two modules.

Address Number Verification

All that remains is to verify that the Master and Slave modules are properly identified. This is accomplished with the Mas-
ter/Slave dip switches located on the input panels. See page 55 for a detailed view of an input panel. The settings were set
at the factory, but it's always a good idea to check the settings.
Normally in a master & slave system the bottom module will be the Master and the other modules will be the Slaves num-
bered 1 & 2 in ascending order. However, as long as the switches are set properly any module can be designated as the
Master. You may, for example, designate the top module as the Master to allow you to bring the signal cables into the top
of the array. Set the switches in accordance with the drawing shown below. On single ICL-FR arrays the dip switches should always be set to
the Master setting ("00").. On "all master" systems, the dip switches should be set to the "master" position on all modules.
Be aware that certain functions will be disabled on the Slave modules as their control has been turned over to the Master module. Preset Up,
Preset Down, Preset Enter , Input Pad, Volume Up & Volume Down, AES/EBU Input and Mute functions are all controlled only by the controls
on the Master module. Signal cables must be brought into the Master module. AC power is brought into each module. Note that if you con-
nected power to the Array before setting the dip switches, you will need to disconnect it and reconnect it before the dip switch settings will take
effect
6
Setting
Setting
for
for
Slave #1
Master
SLAVE
SLAVE
MASTER
MASTER
Setting
for
Slave #2
SLAVE
MASTER