Installation
Electro-static Discharge Precautions
2
Use ESD
Wrist Strap
Installing the Adapter on the Carrier Board
!
Caution
2-2
Motorola strongly recommends that you use an antistatic wrist
strap and a conductive foam pad when installing the MPMC101 or
MPMC102. Electronic components can be extremely sensitive to
electro-static discharge (ESD). After removing the board from the
protective wrapper, place it component side up on a grounded,
static-free surface. Do not slide the board over any surface.
Single-ended and differential SCSI devices are
electronically incompatible and cannot be mixed on the
same physical bus. Mixing single-ended and differential
SCSI devices on the same bus can cause permanent
damage to both the peripherals and the
MPMC101/MPMC102 adapter.
Follow these steps to install the MPMC101/MPMC102 on the
carrier board:
1. Place an ESD strap on your wrist and attach the grounding
line end of the ESD strap to the chassis as a ground. The ESD
strap must be secured to your wrist and to ground
throughout the procedure.
2. Remove the carrier board from the system chassis.
3. Lay the carrier board on a level surface with the PMC
connectors facing you.
4. Remove the PMC slot filler panel from the carrier boardÕs
front panel.