MQRB6961 Combustible Enclosure Heights
Cold Climate Recommendation
When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be
insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and
insulation material to prevent direct contact with the appliance.
See Thru or Single Sided Installation
[Steel Stud Framing Shown.]
Single Side Installation Only
[Steel Stud Framing Shown.]
MQRB6961:
The Wall Thimble Shield Z57WTS is required in
All Enclosures below 78" [Seventy-Eight Inches].
Place Wall Thimble Shield Z57WTS against the
Wall Thimble Immediately above the Vent. Install
the Wall Thimble Shield using [3] DT Screws.
27