Download Print this page
Vibra  ALC 3 Operation Manual

Vibra ALC 3 Operation Manual

Alc series

Advertisement

Quick Links

Tại TP.Hồ Chí Minh
1.
CÔNG TY CỔ PHẦN CÂN ĐIỆN TỬ VIỆT NAM
Địa chỉ : 43 Đường D1 - Phường 25 - Quận Bình Thạnh - TP.HCM
MST :
0312235751
Điện Thoại : (08) 62.888.666 - (08) 3512.7131
Di Động : 0908.444.000 ( Ms Kim Cương)
website :
www.canvietnam.com.vn
2.
CÔNG TY CỔ PHẦN CÂN ĐIỆN TỬ VIBRA VIỆT NAM
Địa Chỉ : 25B4 Đường D1 - Phường 25 - Quận Bình Thạnh - TP.HCM
MST :
0312442243
Điện Thoại : (08) 62.999.111
Di Động : 0908.88.66.11
website :
www.vibra.com.vn
Tại TP.Hà Nội
CHI NHÁNH CÔNG TY CỔ PHẦN CÂN ĐIỆN TỬ VIỆT NAM TẠI HÀ NỘI
Địa Chỉ : Số 3 Dãy D3 - KTT Cơ Khí - Yên Viên - Gia Lâm - Hà Nội
Điện Thoại : (04) 3692.1799
Di Động : 0168.387.3969 ( Ms Kim Hoa)
Tại Bình Thuận
CHI NHÁNH CÔNG TY CỔ PHẦN CÂN ĐIỆN TỬ VIỆT NAM TẠI
BÌNH THUẬN
Địa Chỉ : 49 Bến Chương Dương - Thị Xã LaGi - Tỉnh Bình Thuận
Điện Thoại : (062) 3841.777
Di Động : 0933.996.836 ( Mr Van Xa)

Advertisement

loading

Summary of Contents for Vibra VIBRA ALC 3

  • Page 1 Điện Thoại : (08) 62.888.666 - (08) 3512.7131 Di Động : 0908.444.000 ( Ms Kim Cương) website : www.canvietnam.com.vn CÔNG TY CỔ PHẦN CÂN ĐIỆN TỬ VIBRA VIỆT NAM Địa Chỉ : 25B4 Đường D1 - Phường 25 - Quận Bình Thạnh - TP.HCM MST : 0312442243 Điện Thoại : (08) 62.999.111...
  • Page 2 Capacity Division Pan Size (mm) VIBRA ALC 3 0.1g 230 x 290 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ( 2 ) VIBRA ALC 6 0.2g...
  • Page 3: Special Remarks

    Load cell excitation: 5V DC ,5% 100mA Load cell: 350Ω Operation keypad: 20 Display: LCD, 6 digits, green backlight VIBRA SCALES JSC Operating Temperature: 0~40℃;≤85%RH Fuse: 500mA Power Source: AC 110V/220V (±10%) + DC 6V/4.5AH Rechargeable Battery II. Special Remarks 1.
  • Page 4: Display Explanation

    press to show “Lo”, press numeric key to read the low III. Display Explanation value. This scale can save 5 set of high and low limit value. V. Units Switch Press twice to show “Centr “ and before it disappear ,press to show “Unit”, then Press to exit ,...
  • Page 5: Keyboard Function

    Press : to show Hi, that’s high limit value. V. Keyboard Function Press :to show Li, that’s low limit value. (3) Clear the preset quantity Press to clear all the pre-set value. :Use this key to set and confirm the quantity (4) Save the quantity preset (1) input the preset quantity in the unit weight window.
  • Page 6: Operation

    (III)Recover the factory Set the pan ,hit the this key to clear the display Press key to return the display to zero ,then press Use this key to subtract that the current weight readings is net weight. key to show “Centr” and before it disappear press key to Operation recover the factory set.

This manual is also suitable for:

Vibra alc 6Vibra alc 15Vibra alc 30Vibra alc 2Vibra alc 5Vibra alc 10 ... Show all