Page 1
INSTALLATION AND OPERATION MANUAL HE250 (VB00002 model) US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD FIREPLACE Listed to standards ULC-S610 and UL 127 www.occanada.com Manufactured by: Stove Builder International Inc. 250 rue Copenhague, Saint-Augustin-de-Desmaures (Quebec), Canada, G3A 2H3 After-sale service: 418-908-8002 E-mail: tech@sbi-international.com...
Page 1
INSTALLATION AND OPERATION MANUAL HE250 (VB00002 model) US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD FIREPLACE Listed to standards ULC-S610 and UL 127 www.occanada.com Manufactured by: Stove Builder International Inc. 250 rue Copenhague, Saint-Augustin-de-Desmaures (Quebec), Canada, G3A 2H3 After-sale service: 418-908-8002 E-mail: tech@sbi-international.com...
Page 2
THANK YOU FOR CHOOSING THIS VENTIS WOOD FIREPLACE As one of North America’s largest and most respected wood stove and fireplace manufacturers, Stove Builder International takes pride in the quality and performance of all its products. We want to help you get maximum satisfaction as you use this product.
Page 2
THANK YOU FOR CHOOSING THIS VENTIS WOOD FIREPLACE As one of North America’s largest and most respected wood stove and fireplace manufacturers, Stove Builder International takes pride in the quality and performance of all its products. We want to help you get maximum satisfaction as you use this product.
Ash Removal ..................... 19 4.4.3 Raking Charcoal ....................19 4.4.4 Firing Each New Load Hot ................. 20 4.4.5 Turning Down the Air Supply ................20 4.4.6 Building Different Fires for Different Needs ............21 HE250 - Installation and Operation Manual...
Table of content PART A - OPERATION AND MAINTENANCE ........6 1 Safety Information ................6 Summary of Operation and Maintenance Cautions and Warnings ......6 2 General Information on HE250 (VB00002) ........8 Appliance performance ..................8 General Features ....................9 Zone Heating and How to Make it Work for You ...........
Page 4
8.8.1 Universal Roof Support ..................57 8.8.2 Universal Offset Support ..................57 Installation Instructions for Masonry Application ........... 57 8.10 Supply of Combustion Air ..................58 8.10.1 Air Supply in Conventional Houses ..............59 HE250 - Installation and Operation Manual...
Page 4
Offset Chimney Installation ................55 Angled Wall Radiation Shield ................57 Chimney Support Installation ................57 8.8.1 Universal Roof Support ..................57 8.8.2 Universal Offset Support ..................57 Installation Instructions for Masonry Application ........... 58 HE250 - Installation and Operation Manual...
Keep your sales invoice. We also recommend that you register your warranty online at http://www.occanada.com/en/service-support/warranty- registration Registering your warranty online will help us track rapidly the information we need on your unit. HE250 - Installation and Operation Manual...
Keep your sales invoice. We also recommend that you register your warranty online at http://www.occanada.com/en/service-support/warranty- registration Registering your warranty online will help us track rapidly the information we need on your unit. HE250 - Installation and Operation Manual...
FINE PAPER, COLORED PAPER OR CARDBOARD, o SALT WATER DRIFTWOOD, o MANUFACTURED LOGS CONTAINING WAX OR CHEMICAL ADDITIVES, o RAILROAD TIES OR o LIQUIDS SUCH AS KEROSCENE OR DIESEL FUEL TO START A FIRE. HE250 - Installation and Operation Manual...
LIQUIDS SUCH AS KEROSCENE OR DIESEL FUEL TO START A FIRE. THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH • THESE INSTRUCTIONS. DO NOT ELEVATE THE FIRE BY MEANS OF GRATES, ANDIRONS OR OTHER MEANS. • HE250 - Installation and Operation Manual...
Page 7
“mobile home” as followed; Buildings built on fixed wheels and those transported on temporary wheels/axles and set on a permanent foundation. PLEASE NOTE THAT THE PICTURES SHOWN IN THIS MANUAL ARE GENERIC AND MAY NOT MATCH EXACTLY THE LOOK OF YOUR FIREPLACE. HE250 - Installation and Operation Manual...
Page 7
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov/ HE250 - Installation and Operation Manual...
We also test using the same procedure except using split hardwood firewood to reflect real-world heat output. This fireplace is not intended to operate at its peak heat output continuously. *** East-west: through the door you see the sides of the logs. HE250 - Installation and Operation Manual...
2 GENERAL INFORMATION ON HE250 (VB00002) 2.1 Appliance performance Fuel type Dry cordwood Recommended heating area 500 to 2,100 ft (46 to 195 m Firebox volume 2.5 ft (0.071 m Maximum burn time Maximum heat output (dry cordwood) 75,000 BTU/h (22.0 kW) Overall heat output rate (min.
Page 9
8”/203mm HOT AIR GRAVITY DISTRIBUTION KIT (2) HE250 - Installation and Operation Manual...
Page 9
CAN/CSA-Z240 MH standard. 8”/203mm HOT AIR GRAVITY DISTRIBUTION KIT (2) HE250 - Installation and Operation Manual...
Page 10
6”/142mm FORCED AIR DISTRIBUTION KIT (3) HE250 - Installation and Operation Manual...
Page 10
6”/142mm FORCED AIR DISTRIBUTION KIT (3) HE250 - Installation and Operation Manual...
2.2 Zone Heating and How to Make it Work for You Your new HE250 wood fireplace is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature. This is called zone heating and it is an increasingly popular way to heat homes or spaces within homes.
2.3 Zone Heating and How to Make it Work for You Your new HE250 wood fireplace is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature. This is called zone heating and it is an increasingly popular way to heat homes or spaces within homes.
2.3 The Benefits of Low Emissions and High Efficiency The low smoke emissions produced by the special features inside the HE250 firebox mean that your household will release up to 90 percent less smoke into the outside environment than if you used an older conventional stove.
2.4 The Benefits of Low Emissions and High Efficiency The low smoke emissions produced by the special features inside the HE250 firebox mean that your household will release up to 90 percent less smoke into the outside environment than if you used an older conventional stove.
Old, leaky cast iron stoves wouldn’t hold a fire overnight unless they were fed large pieces of hardwood. That is no longer true. You can successfully heat your home by using the less desirable tree species and give the forest a break at the same time. HE250 - Installation and Operation Manual...
Old, leaky cast iron stoves wouldn’t hold a fire overnight unless they were fed large pieces of hardwood. That is no longer true. You can successfully heat your home by using the less desirable tree species and give the forest a break at the same time. HE250 - Installation and Operation Manual...
Often, the firewood purchased from commercial suppliers is not split finely enough for convenient stoking. It is sometimes advisable to resplit the wood before stacking to dry. HE250 - Installation and Operation Manual...
Often, the firewood purchased from commercial suppliers is not split finely enough for convenient stoking. It is sometimes advisable to resplit the wood before stacking to dry. HE250 - Installation and Operation Manual...
Start with one manufactured log and see how the fireplace reacts. Never use more than two manufactured logs at a time. HE250 - Installation and Operation Manual...
Start with one manufactured log and see how the fireplace reacts. Never use more than two manufactured logs at a time. HE250 - Installation and Operation Manual...
Once the fire has ignited, close the door and leave the air control fully open. A conventional kindling fire with paper under finely split wood. HE250 - Installation and Operation Manual...
A conventional kindling fire with paper under finely split wood. DO NOT LEAVE THE FIREPLACE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED. ALWAYS CLOSE AND LATCH THE DOOR AFTER THE FIRE IGNITES. HE250 - Installation and Operation Manual...
For example, the area temperature can be cooler when you are active, such as when doing housework or cooking, and it can be warmer when you are inactive, such as when reading or watching television. HE250 - Installation and Operation Manual...
If you were to simply spread the charcoal out, the new load will smoulder for a long time before igniting. Remove ash first, and then rake charcoal towards the front of the firebox before loading so that it will ignite the new load. HE250 - Installation and Operation Manual...
If you were to simply spread the charcoal out, the new load will smoulder for a long time before igniting. Remove ash first, and then rake charcoal towards the front of the firebox before loading so that it will ignite the new load. HE250 - Installation and Operation Manual...
With good fuel and correct air control use, the flames should slow down, but should stay large and steady, even as the air supply is reduced. HE250 - Installation and Operation Manual...
With good fuel and correct air control use, the flames should slow down, but should stay large and steady, even as the air supply is reduced. HE250 - Installation and Operation Manual...
You will need to fire the load hot for long enough to fully char the log surfaces before you can turn the air down. Make sure the fire is flaming brightly before leaving the fire to burn. HE250 - Installation and Operation Manual...
You will need to fire the load hot for long enough to fully char the log surfaces before you can turn the air down. Make sure the fire is flaming brightly before leaving the fire to burn. HE250 - Installation and Operation Manual...
Page 22
North-south loads break down more quickly, but much more wood can be loaded at a time. This makes north-south loading good for high output, long lasting fires for cold weather. HE250 - Installation and Operation Manual...
Page 22
North-south loads break down more quickly, but much more wood can be loaded at a time. This makes north-south loading good for high output, long lasting fires for cold weather. HE250 - Installation and Operation Manual...
Visit your fireplace retailer to get the self-adhesive glass gasket and follow the instructions below for installation. Do not abuse the glass door by striking or slamming shut. Do not use the fireplace if the glass is broken. HE250 - Installation and Operation Manual...
Visit your fireplace retailer to get the self-adhesive glass gasket and follow the instructions below for installation. Do not abuse the glass door by striking or slamming shut. Do not use the fireplace if the glass is broken. HE250 - Installation and Operation Manual...
5.1.4 Door Alignment To align, open the fireplace’s door and loosen the pressures screws located on the lower and upper hinges of the door using a 3/32” Allen key to free the adjustable hinge rods. HE250 - Installation and Operation Manual...
5.1.4 Door Alignment To align, open the fireplace’s door and loosen the pressures screws located on the lower and upper hinges of the door using a 3/32” Allen key to free the adjustable hinge rods. HE250 - Installation and Operation Manual...
Page 25
Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. HE250 - Installation and Operation Manual...
Page 25
Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. HE250 - Installation and Operation Manual...
Rond 1" (2,54 cm) The glass used in the HE250 is 5 mm thick of dimension: 25 3/8” x 13’’ and tested to reach temperatures up to 1400º F. If the glass breaks, it must be replaced with one having the same specification. Contact your Ventis dealer to obtain a genuine replacement part (see “replacement parts”, in appendix to get the proper...
Round 1" (2,54 cm) The glass used in the HE250 is 5 mm thick of dimension: 25 3/8” x 13’’ and tested to reach temperatures up to 1400º F. If the glass breaks, it must be replaced with one having the same specification. Contact your Ventis dealer to obtain a genuine replacement part (see “replacement parts”, in appendix to get the proper...
Even if creosote forms slowly in your system, the chimney should be cleaned and inspected at least once each year. Do not allow more than 1/8″ (3 mm) creosote buildup in the chimney. HE250 - Installation and Operation Manual...
Your new fireplace has the right characteristics to help you to burn clean fires with little or no smoke, resulting in less creosote in the chimney. HE250 - Installation and Operation Manual...
4) Clean the inside of the firebox. 5) Re-install the baffle, the air tubes and the rain cap. CAUTION: OPERATION OF YOUR HE250 WITHOUT THE BAFFLE MAY CAUSE UNSAFE AND HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY. HE250 - Installation and Operation Manual...
4) Clean the inside of the firebox. 5) Re-install the baffle, the air tubes and the rain cap. CAUTION: OPERATION OF YOUR HE250 WITHOUT THE BAFFLE MAY CAUSE UNSAFE AND HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY. HE250 - Installation and Operation Manual...
5. Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting the roof; 6. Do not use the fireplace again until your chimney and fireplace have been inspected by a qualified chimney sweep or a Fire Department Inspector; HE250 - Installation and Operation Manual...
5. Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting the roof; 6. Do not use the fireplace again until your chimney and fireplace have been inspected by a qualified chimney sweep or a Fire Department Inspector. HE250 - Installation and Operation Manual...
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. • THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED IN A MOBILE HOME. • THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED INSIDE A MASONRY CHIMNEY. • HE250 - Installation and Operation Manual...
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. • THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED IN A MOBILE HOME. • THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED INSIDE A MASONRY CHIMNEY. • HE250 - Installation and Operation Manual...
6.2 Regulations Covering Fireplace Installation When installed and operated as described in these instructions, the HE250 wood fireplace is suitable for use in residential installations. The HE250 wood fireplace is not intended for installation in a bedroom of a mobile home.
6.2 Regulations Covering Fireplace Installation When installed and operated as described in these instructions, the HE250 wood fireplace is suitable for use in residential installations. The HE250 wood fireplace is not intended for installation in a bedroom of a mobile home.
6.3.1.1 Raised base installation of more than 4" (R value for the hearth extension not required) The HE250 may be installed directly on the floor or on a raised combustible or non combustible base. If the fireplace is elevated more than 4" (B), an R value for the hearth extension is not required. However, the upper and lower angle, for the full width of the floor protection, must be protected 2"...
B. Usually, no additional floor support is needed for the fireplace. The adequacy of the floor can be checked by first estimating the weight of the fireplace system. Weight is given in Section 2.1: HE250 Specifications. Next, measure the area occupied by the fireplace, note the floor construction and consult your local building code to determine if additional support is needed.
Page 33
6.3.1.1 Raised base installation of more than 4" (R value for the hearth extension not required) The HE250 may be installed directly on the floor or on a raised combustible or non-combustible base. If the fireplace is elevated more than 4" (B), an R value for the hearth extension is not required. However, the upper and lower angle, for the full width of the floor protection, must be protected 2"...
Page 34
HE250 - Installation and Operation Manual...
Page 34
HE250 - Installation and Operation Manual...
Page 35
In the case where (F) would be equal to 4", it is suggested that the sheet metal between the base of the fireplace and floor be in one piece. HE250 - Installation and Operation Manual...
Page 35
In the case where (F) would be equal to 4", it is suggested that the sheet metal between the base of the fireplace and floor be in one piece. HE250 - Installation and Operation Manual...
Page 36
(E) must be protected by a non-combustible material. For example, a sheet metal (not included). Note that the floor under of the fireplace should match or exceed the height of the floor protection. MINIMUM MEASUREMENT 2" (51 mm) HE250 - Installation and Operation Manual...
Page 36
This is because R values are additive, whereas K values are not. To find the corresponding R factor to use for some selected materials, please see Thermal Characteristics of Common Floor Protection Materials table. CAUTION: DO NOT LEAVE CARPET UNDER THE FLOOR PROTECTION IN FRONT OF THE FIREPLACE HE250 - Installation and Operation Manual...
Page 37
R by dividing the thickness of each material by its K value. Add the R values of your proposed materials as shown in the previous example. Example: K value = 0.75 Thickness = 1 R value = Thickness/K = 1/0.75 = 1.33 HE250 - Installation and Operation Manual...
Page 37
R by dividing the thickness of each material by its K value. Add the R values of your proposed materials as shown in the previous example. Example: K value = 0.75 Thickness = 1 R value = Thickness/K = 1/0.75 = 1.33 HE250 - Installation and Operation Manual...
(not included). * On a raised base installation of more than 4", a non-combustible hearth extension floor area must extend at least 16" (406 mm) in front of the hearth. HE250 - Installation and Operation Manual...
* Information as reported by manufacturers and other resources. ** For a 1/8" thickness. You cannot «stack» horizontal still air to accumulate R-values; you must separate each layer of horizontal still air with another non-combustible material. HE250 - Installation and Operation Manual...
Page 39
18" (457 mm)* 41.5" (1054 mm) 8" (203 mm) *On a raised base installation of more than 4", a non-combustible hearth extension floor area must extend at least 16" (406 mm) in front of the hearth. HE250 - Installation and Operation Manual...
Page 39
8" (203 mm) on each side of the door opening (D). The joint between the hearth extension and the fireplace hearth needs to be made of non-combustible material such as sheet metal (not included). CLEARANCES 16" (406 mm) 41.5" (1054 mm) 8" (203 mm) HE250 - Installation and Operation Manual...
WARNING: THE FIREPLACE MUST NOT BE IN CONTACT WITH ANY INSULATION OR LOOSE FILLING MATERIAL. FOR THIS PURPOSE, COVER THE INSULATION WITH DRYWALL PANELS OR ANY OTHER FINISHING MATERIAL INSIDE THE CHASE AROUND THE FIREPLACE. HE250 - Installation and Operation Manual...
THE FIREPLACE MUST NOT BE IN CONTACT WITH ANY INSULATION OR LOOSE FILLING MATERIAL. FOR THIS PURPOSE, COVER THE INSULATION WITH DRYWALL PANELS OR ANY OTHER FINISHING MATERIAL INSIDE THE CHASE AROUND THE FIREPLACE. HE250 - Installation and Operation Manual...
Page 41
1 3/8" (35 mm) MAX 5" (127 mm) 80" (2032 mm) *When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. HE250 - Installation and Operation Manual...
Page 41
1 3/8" (35 mm) MAX 5" (127 mm) 80" (2032 mm) *When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. HE250 - Installation and Operation Manual...
Page 42
*When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. ** The fresh air intake kit and the forced air distribution kit may be installed either on the sides or on the back. HE250 - Installation and Operation Manual...
Page 42
*When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. ** The fresh air intake kit and the forced air distribution kit may be installed either on the sides or on the back. HE250 - Installation and Operation Manual...
Page 43
**Values M and N are minimum measurements. They may need to be increased to alloy installation of a fresh air intake kit or forced air kit, or depending on the finish material used. CLEARANCES 3" (76 mm) maximum 5 5/8" (143 mm) minimum 24" (610 mm) minimum HE250 - Installation and Operation Manual...
Page 43
**Values M and N are minimum measurements. They may need to be increased to alloy installation of a fresh air intake kit or forced air kit, or depending on the finish material used. CLEARANCES 3" (76 mm) maximum 5 5/8" (143 mm) minimum 24" (610 mm) minimum HE250 - Installation and Operation Manual...
Page 44
52" (1321 mm) to the depth of your mantel shelf to obtain the safe positioning of your mantel shelf. For example, for a 9" (229 mm) mantel shelf, the safe positioning would be 61" (1549 mm) above the bottom of the fireplace 52" (1321 mm) + 9" (229 mm)). HE250 - Installation and Operation Manual...
Page 44
52" (1321 mm) to the depth of your mantel shelf to obtain the safe positioning of your mantel shelf. For example, for a 9" (229 mm) mantel shelf, the safe positioning would be 61" (1549 mm) above the bottom of the fireplace 52" (1321 mm) + 9" (229 mm). HE250 - Installation and Operation Manual...
In addition, you will find information about your fireplace (model, serial number, etc.). You can find the certification label under the fireplace, behind the bottom louver. HE250 - Installation and Operation Manual...
In addition, you will find information about your fireplace (model, serial number, etc.). You can find the certification label under the fireplace, behind the bottom louver. HE250 - Installation and Operation Manual...
2. The HE250 is listed only with chimney systems described in table 1. 3. A chimney venting a fireplace shall not vent any other appliance.
Page 49
12. For installations where more than one chimney is located in the same non-chase or within the same area, we suggest that their terminations be separated by at least 16" (410 mm) horizontally, and 18" (460 mm) vertically. This separation is to prevent smoke migrating from one chimney to another. HE250 - Installation and Operation Manual...
Page 49
11. Portions of the chimney which may extend through accessible spaces must be enclosed to avoid contact with combustible materials or damage the chimney. HE250 - Installation and Operation Manual...
16" (410 mm) horizontally, and 18" (460 mm) vertically. This separation is to prevent smoke migrating from one chimney to another. 18" 18" 457.2mm 457.2mm 18" 457.21mm 16" 16" 406.4mm 406.4mm HE250 - Installation and Operation Manual...
However, starting using a 30° or 45° elbow is also approved. Mandatory measure of 15 ft. from the bottom of the fireplace to the top of the outside chimney. HE250 - Installation and Operation Manual...
However, starting using a 30° or 45° elbow is also approved. Mandatory measure of 15 ft. from the bottom of the fireplace to the top of the outside chimney. HE250 - Installation and Operation Manual...
Page 52
Direct installation Exterior offset installation HE250 - Installation and Operation Manual...
Page 52
Direct installation Exterior offset installation HE250 - Installation and Operation Manual...
Page 53
4. Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach the desired height, install the roof support (not illustrated). (Refer to instructions included with the support). HE250 - Installation and Operation Manual...
Page 53
4. Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach the desired height, install the roof support (not illustrated). (Refer to instructions included with the support). HE250 - Installation and Operation Manual...
Page 54
8. When a ventilated roof flashing is installed, precautions are to be taken not to caulk or seal the ventilating openings. THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED NOTE: THE FLOOR AND WALLS BELOW THE ATTIC MUST BE INSULATED USING THE SAME INSULATION. HE250 - Installation and Operation Manual...
Page 54
8. When a ventilated roof flashing is installed, precautions are to be taken not to caulk or seal the ventilating openings. THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED NOTE: THE FLOOR AND WALLS BELOW THE ATTIC MUST BE INSULATED USING THE SAME INSULATION. HE250 - Installation and Operation Manual...
5. From below, install a firestop supplied by the chimney manufacturer (see preceding figure). 6. A support must be used on the first 15' section (4.6 m). 7. Continue with the regular installation. TABLE 2 - LISTED CHIMNEYS FOR YOUR HE250 CHIMNEY BRAND...
5. From below, install a firestop supplied by the chimney manufacturer (see preceding figure). 6. A support must be used on the first 15' section (4.6 m). 7. Continue with the regular installation. HE250 - Installation and Operation Manual...
Only one is required. Follow the chimney manufacturer’s installation instructions. In cold climate locations, it is recommended that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier. INSULATED WALL RADIATION SHIELD GYPROCK INSULATED WALL HE250 - Installation and Operation Manual...
For connection at 30 or 45° angle, a special connector (B) must be used to connect the liner (C) to the insulated chimney (A). Verify availability and installation instructions for this connector with the chimney manufacturer. HE250 - Installation and Operation Manual...
Many manufacturers will provide the maximum height of chimney that can be supported by the support. Make sure you respect those parameters. HE250 - Installation and Operation Manual...
(CO) detector/alarm is required in the room in which the fireplace is installed. The CO detector will provide warning if for any reason the wood fireplace fails to function correctly. HE250 - Installation and Operation Manual...
The chimney must be relined with a Forever Flex or Hybrid stainless steel liner of the same diameter as the outlet of the fireplace. Only a connection at 30 ° or 45° angle is allowed. A special connector (B) must be used to connect the liner (C) to the insulated chimney (A). HE250 - Installation and Operation Manual...
Check the outdoor air duct for soot deposits when the full system is cleaned and inspected at least once each year. HE250 - Installation and Operation Manual...
12. To complete installation, secure the elbow or chimney section to the fireplace anchor plate.Note: Make sure the liner exceeds at least 12” (30 cm) the top of masonry chimney. CVA-UMA0630/ CVA-UMA0645 CACLF6/ CUCHF6 CVA-CPEC06 HE250 - Installation and Operation Manual...
APPENDIX 1: OPTIONAL HEAT DISTRIBUTION SYSTEMS INSTALLATION Different heat distribution systems can be installed with the HE250: • Hot air gravity distribution kit - Traditional style (AC01375) • Hot air gravity distribution kit - Modern style (AC01385) • Forced air distribution kit...
Check the outdoor air duct for soot deposits when the full system is cleaned and inspected at least once each year. HE250 - Installation and Operation Manual...
Page 61
68" (1.7 m) Minimum distance from ceiling: 12’’ (30 cm) Maximum length: 10' (3m) *The minimum height of the hot air ducting must be measured from the floor to the top of the hot air grilles. HE250 - Installation and Operation Manual...
Page 61
APPENDIX 1: OPTIONAL HEAT DISTRIBUTION SYSTEMS INSTALLATION Different heat distribution systems can be installed with the HE250: • Hot air gravity distribution kit - Traditional (AC01375) • Hot air gravity distribution kit - Modern with adjustable pipes (AC01389) • Forced air distribution kit...
Page 62
The hot air grilles can be installed in the same room as the fireplace, or one or both of the grilles can be installed in adjacent or upper rooms. Installing the ducts at different elevations will tend to exhaust more heat out of the higher grilles. HE250 - Installation and Operation Manual...
Page 62
68" (1.7 m) Minimum distance from ceiling: 12’’ (30 cm) Maximum length: 10' (3m) *The minimum height of the hot air ducting must be measured from the floor to the top of the hot air grilles. HE250 - Installation and Operation Manual...
Page 63
2. Secure the 6 steel brackets (B) with 6 screws provided (C) on top of the fireplace (3 for each ducting). Insert the ducting (A) (not provided) into each opening and secure it in place using the steel brackets (B) installed previously with 6 other self-tapping screws provided (C). HE250 - Installation and Operation Manual...
Page 63
The hot air grilles can be installed in the same room as the fireplace, or one or both of the grilles can be installed in adjacent or upper rooms. Installing the ducts at different elevations will tend to exhaust more heat out of the higher grilles. HE250 - Installation and Operation Manual...
Page 64
7. When passing through a combustible wall or floor, a firestop must be installed at the wall or floor penetration. The hole size must be in accordance with the duct manufacturer’s instructions. HE250 - Installation and Operation Manual...
Page 64
2. Secure the 6 steel brackets (B) with 6 screws provided (C) on top of the fireplace (3 for each ducting). Insert the ducting (A) (not provided) into each opening and secure it in place using the steel brackets (B) installed previously with 6 other self-tapping screws provided (C). HE250 - Installation and Operation Manual...
Page 65
12. The hot air outlet grilles must be installed with the louvers pointing downwards in order to prevent overheating adjacent ceilings. 13. Always install the two outlet grilles when using the hot air gravity distribution kit and blocking the upper louver of the fireplace. HE250 - Installation and Operation Manual...
Page 65
7. When passing through a combustible wall or floor, a firestop must be installed at the wall or floor penetration. The hole size must be in accordance with the duct manufacturer’s instructions. HE250 - Installation and Operation Manual...
Page 66
6 X steel brackets (D) with fastening screws (E) and 12 X self-tapping screws (F) 2 X Finishing cap assemblies (H) AND (J) 2 X Fastening screws (I) Parts not included in the kit: 2 X 8” rigid ducting (G) HE250 - Installation and Operation Manual...
Page 66
12. The hot air outlet grilles must be installed with the louvers pointing downwards in order to prevent overheating adjacent ceilings. 13. Always install the two outlet grilles when using the hot air gravity distribution kit and blocking the upper louver of the fireplace. HE250 - Installation and Operation Manual...
Page 67
DIMENSIONS OF HEAT DISTRIBUTION BOX: DIMENSIONS OF ASSEMBELED DECORATIVE PLATE: HE250 - Installation and Operation Manual...
Page 67
Decorative plate (A) Adjustable frame (B) Heat distribution box (C) Telescoping section (D) Anchor plate (E) All screws are included Parts not included in the kit: 8” rigid ducting (if required according to the desired height). HE250 - Installation and Operation Manual...
Page 68
1. It is recommended to wear gloves to perform this procedure. Remove the plates closing up the 8" dia. holes on top of the fireplace. Then, cut and remove the insulation in order to obtain two 8" dia. openings. Then, remove the plates closing up the 8" dia. holes inside the fireplace. HE250 - Installation and Operation Manual...
Page 68
DIMENSIONS OF HEAT DISTRIBUTION BOX: DIMENSIONS OF ADJUSTABLE DECORATIVE PLATE: HE250 - Installation and Operation Manual...
Page 69
4 screws into the heat distribution box. Set the decorative plate (G) to the adjustable frame (F) with fastening screws (I) and finishing cap assemblies (H) and (J) provided in the kit. HE250 - Installation and Operation Manual...
Page 69
DIMENSIONS OF ASSEMBLED HEAT DISTRIBUTION BOX AND ADJUSTABLE DECORATIVE PLATE: DIMENSIONS OF TELESCOPING SECTION Min. HE250 - Installation and Operation Manual...
Page 70
Forced Air Distribution Kit (not tested to EPA Standards) (AC01340) It is possible to connect a forced air distribution kit (AC01340) on the back or on either sides of the HE250. This kit allows distributing heat to another room up to 50 feet (15 m) of the fireplace. The insulated flexible pipe (not included in the kit) must be HVAC type pipe and must comply with ULC S110 and/or UL 181, Class 0 or Class 1 Standards and must withstand temperatures up to 250 °F.
Page 70
(C) with 8 screws provided (B) on top of the fireplace (4 for each anchor plate). Insert the telescoping section (A) into each anchor plate and secure it with 6 other self- tapping screws provided (B). HE250 - Installation and Operation Manual...
APPENDIX 2: BLOWER MAINTENANCE OR REPLACEMENT 1. Open the bottom louver (A). 2. With a short square head screwdriver, remove the 4 screws (C) holding in place the heat shield (B). HE250 - Installation and Operation Manual...
3 self-tapping screws provided. Insert the adjustable frame (D) in the heat distribution box (C), press it against the non-combustible finishing material and secure with 4 screws into the heat distribution box. Set the decorative plate (E) to the adjustable frame (D). HE250 - Installation and Operation Manual...
Page 72
3. Remove and keep the heat shield (B) and the 4 screws (C). 4. Cut the Tie wrap (D) HE250 - Installation and Operation Manual...
Page 72
Forced Air Distribution Kit* (AC01340) It is possible to connect a forced air distribution kit (AC01340) on the back or on either sides of the HE250. This kit allows distributing heat to another room up to 50 feet (15 m) of the fireplace. The insulated flexible pipe (not included in the kit) must be HVAC type pipe and must comply with ULC S110 and/or UL 181, Class 0 or Class 1 Standards and must withstand temperatures up to 250 °F.
Page 73
5. Unplug the blower’s electric wires (F) and (G). 6. Lift the blower (E) located under the firebox towards the back. 7. Turn 90° to pull out. Repeat the steps in reverse order to reinstall the fan. HE250 - Installation and Operation Manual...
Page 73
APPENDIX 2: BLOWER MAINTENANCE OR REPLACEMENT 1. Open the bottom louver (A). 2. With a short square head screwdriver, remove the 4 screws (C) holding in place the heat shield (B). HE250 - Installation and Operation Manual...
Page 74
Connect the black wire with the black wire of the terminal block. The ground (green or skinned wire) must be attached to the fireplace metal frame. HE250 - Installation and Operation Manual...
Page 74
3. Remove and keep the heat shield (B) and the 4 screws (C). 4. Cut the Tie wrap (D). HE250 - Installation and Operation Manual...
APPENDIX 3: INSTALLING THE OPTIONAL DOOR OVERLAY In order to complete the assembly of your HE250 wood fireplace, you need to install the door overlay. See figure below for installation instructions: Position the overlay (A) and on the door frame and secure from the inside of the door using the 6 included screws (B) and bolts (C).
Connect the black wire with the black wire of the terminal block. The ground (green or skinned wire) must be attached to the fireplace metal frame. HE250 - Installation and Operation Manual...
A 3” or 4” insulated flexible pipe (This HVAC type pipe must comply to ULC S110 and/or UL 181, Class 0 or Class 1 Standards and must withstand temperatures up to 250 °F. HE250 - Installation and Operation Manual...
APPENDIX 3: INSTALLING THE OPTIONAL DOOR OVERLAY In order to complete the assembly of your HE250 wood fireplace, you need to install the door overlay. See figure below for installation instructions: Position the overlay (A) and on the door frame and secure from the inside of the door using the 6 included screws (B) and bolts (C).
Page 77
If the location 2 or 3 has been chosen, use pliers to remove the knock- out. 2. Secure the fresh air intake kit adapter (B) on the fireplace jacket using the 4 screws provided with the kit. HE250 - Installation and Operation Manual...
Page 77
A 3” or 4” insulated flexible pipe (This HVAC type pipe must comply to ULC S110 and/or UL 181, Class 0 or Class 1 Standards and must withstand temperatures up to 250 °F. HE250 - Installation and Operation Manual...
Page 78
"P-Trap" loop. This configuration can be found inside the chase, but must at all times maintain clearances to combustibles. HE250 - Installation and Operation Manual...
Page 78
If the location 2 or 3 has been chosen, use pliers to remove the knock- out. 2. Secure the fresh air intake kit adapter (B) on the fireplace jacket using the 4 screws provided with the kit. HE250 - Installation and Operation Manual...
Page 79
For a better seal, you may also use aluminum tape. Wrap the tape around the joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in place using aluminum tape. HE250 - Installation and Operation Manual...
Page 79
"P-Trap" loop. This configuration can be found inside the chase, but must at all times maintain clearances to combustibles. HE250 - Installation and Operation Manual...
Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the fire screen. HE250 - Installation and Operation Manual...
For a better seal, you may also use aluminum tape. Wrap the tape around the joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in place using aluminum tape. HE250 - Installation and Operation Manual...
(x4) Air tubes (x4) C-cast baffle (x1) Baffle insulation (x1) Baffle insulation weight (x1) 1. Using a ratchet key and a Torx (T-30), unscrew the two Torx screws (B) holding up the andiron (A). HE250 - Installation and Operation Manual...
Lift the firescreen upwards and push the bottom part towards the stove then let the firescreen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the firescreen. HE250 - Installation and Operation Manual...
Page 82
2. Remove the floor refractory slab (C). 3. Using a power screwdriver and hex tip 5/16", remove the slab holder left refractory slab (E). HE250 - Installation and Operation Manual...
Page 82
(x4) Air tubes (x4) C-cast baffle (x1) Baffle insulation (x1) Baffle insulation weight (x1) 1. Using a ratchet key and a Torx (T-30), unscrew the two Torx screws (B) holding up the andiron (A). HE250 - Installation and Operation Manual...
Page 83
5. Align the notch in the left end of the tube with the tab of the left air channel hole. HE250 - Installation and Operation Manual...
Page 83
2. Remove the floor refractory slab (C). 3. Using a power screwdriver and hex tip 5/16", remove the slab holder left refractory slab (E). HE250 - Installation and Operation Manual...
Page 84
The air tubes are identified for placement as follows: Model Type of tube HE250 fireplace Front ► 95 holes of 0.141" Middle front ► 67 holes of 0.125’’ Middle rear ► 67 holes of 0.109’’ Rear ► 67 holes of 0.101’’ HE250 - Installation and Operation Manual...
Page 84
5. Align the notch in the left end of the tube with the tab of the left air channel hole. HE250 - Installation and Operation Manual...
Then, install the two front tubes. 8. To remove the tubes use the above steps in reverse order. Note that secondary air tubes can be replaced without removing the baffle board. HE250 - Installation and Operation Manual...
Page 86
6" VENTIS ANCHOR PLATE 31 PL63766 HEADER STAND OFF 32 PL66500 TOP HEAT SHIELD 33 PL53065 REAR SPACER 34 PL63768 SIDE REAR SPACER 35 PL63767 SIDE FRONT SPACER 36 44046 THERMODISC F110-20F 37 99999 BUILD TO ORDER HE250 - Installation and Operation Manual...
Page 86
If large cracks develop, then the refractory slabs should be replaced. To replace the refractory slabs, follow these steps: 1- Using a ratchet key and a Torx (T-30) socket, unscrew the two Torx screws (B) holding up the andiron (A). 2- Remove the floor refractory slab (C). HE250 - Installation and Operation Manual...
Page 87
67 AC01375 AIR GRAVITY KIT - TRADITONAL STYLE 68 49066 90° X 8" 26Ga. GALVANISED ELBOW 69 30640 DISTRIBUTION GAKLVANISED BOX FOR HOT AIR GRAVITY KIT 8" 70 30540 DISTRIBUTION HOT AIR GRAVITY KIT GRILL HE250 - Installation and Operation Manual...
Page 87
3- Using a power screwdriver and hex tip 5/16", remove the slab holders (D) and the refractory slabs (E) and (F). 4- Remove the rear refractory slab (G). To install new refractory slabs, follow the above steps in reverse. HE250 - Installation and Operation Manual...
Page 88
If large cracks develop, then the refractory slabs should be replaced. To replace the refractory slabs, follow these steps: 1- Using a ratchet key and a Torx (T-30) socket, unscrew the two Torx screws (B) holding up the andiron (A). 2- Remove the floor refractory slab (C). HE250 - Installation and Operation Manual...
Page 88
APPENDIX 8: EXPLODED DIAGRAM AND PARTS LIST HE250 - Installation and Operation Manual...
Page 89
3- Using a power screwdriver and hex tip 5/16", remove the slab holders (D) and the refractory slabs (E) and (F). 4- Remove the rear refractory slab (G). To install new refractory slabs, follow the above steps in reverse. HE250 - Installation and Operation Manual...
Page 89
31 PL63766 HEADER STAND OFF 32 PL66500 TOP HEAT SHIELD 33 PL53065 REAR SPACER 34 PL63768 SIDE REAR SPACER 35 PL63767 SHORT SIDE STANDOFF 36 44028 CERAMIC THERMODISC F110-20F 37 99999 BUILD TO ORDER HE250 - Installation and Operation Manual...
Paint (peeling), gaskets, insulation, firebrick, and ceramic fibre blankets. 1 year *Pictures required Shall your unit or a components be defective, contact immediately your VENTIS dealer. Prior to your call make sure you have the following information necessary to your warranty claim treatment: •...
GAKLVANISED BOX FOR HOT AIR GRAVITY DISTRIBUTION KIT 8" 70 30540 HOT AIR GRAVITY DISTRIBUTION KIT GRILL 71 PL53026 AIR INTAKE BOX COVER 72 30154 BLACK SCREW #10 X 5/8" QUADREX #2 TYPE A 73 SE66579 REPLACEMENT HE250 HANDLE KIT HE250 - Installation and Operation Manual...
Need help?
Do you have a question about the HE250 and is the answer not in the manual?
Questions and answers