Installer: Leave this manual with the party responsible for use and operation.
This Fireplace uses 8" Ventis Class-A Factory Built Chimney Systems. A 2" clearance to
combustibles and building insulation is required between the chimney pipe and any combustible
material.
WARNING! FIRE RISK:
For use with solid wood fuel,
processed solid fuel fire logs,
unvented decorative gas logs, or vented gas
logs only. Other fuels may overfire and
generate poisonous gases.
Owner: Retain this manual for future reference.
Models:
OCV-RR-36
OCV-RR-42
Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4
WARNING! The information in this
manual must be followed exactly or
a fire or explosion may result which can
cause property damage, injury, or death.
 DO NOT over fire this fireplace as it will void your
warranty.
 DO NOT store or use gasoline or other flammable
liquids in the vicinity of this fireplace.
 All clearances to combustibles in this manual
must be followed exactly. A failure to comply may
result in a house fire.
WARNING! HOT SURFACES!
Glass and other surfaces are hot
during operation and cool down.
 DO NOT touch the glass until it is cooled
 Keep children away from the fireplace
 Carefully supervise children that are in the same
room as the fireplace
WARNING! HIGH TEMPERATURES!
Alert adults and children to the
hazards of high temperatures.
 High temperatures may ignite clothing or other
flammable materials.
 Keep clothing, furniture, drapes, and other
flammable materials away from the fireplace.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OCV-RR-36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ventis OCV-RR-36

  • Page 1 Installer: Leave this manual with the party responsible for use and operation. Owner: Retain this manual for future reference. This Fireplace uses 8” Ventis Class-A Factory Built Chimney Systems. A 2” clearance to combustibles and building insulation is required between the chimney pipe and any combustible material.
  • Page 2: Table Of Contents

    31. Gas Log Conversion ................22 32. Assembling Loose Parts/Brackets ............ 23 Refractory Panel Retaining Clips ............23 Log Grate ..................23 Wall Stud Nailing Flanges ..............23 33. Replacement Firebox Components ..........24 Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 3: General Product & Safety Information

    • Install the fireplace in a way that does not surface. follow this manual. • Over fire the fireplace. • Install venting that is not listed with this fireplace. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 4: Fireplace Location Selection

    Locating the fireplace near frequently opened doors, a central heat outlet or other areas that have considerable air movement can affect the fireplace performance. Please take these factors into consideration prior to deciding on a location. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 5: Fireplace & Chimney Location

    • Ventis Termination Cap – sold separately system and may void the warranty. Do not attempt matching components with another manufacturer’s products. Do not use damage or modified parts. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 6: Safety Considerations

    Be sure that the chimney does not come into contact with electrical or any other wires. Warning: Do not block air circulation vents on either side of the fire chamber. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 7: Fireplace Dimensions

    9. Fireplace Dimensions Model OCV-RR-36 35-5/8 23-7/8 11-15/16 OCV-RR-42 41-5/8 29-7/8 14-15/16 Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 8: Clearances

    0” Door opening to side wall 12” Fireplace opening to combustible materials 48” Mantel Minimum Mantel Height 12” Maximum Mantel Depth 12” Minimum Mantel Width (OCV-RR-36) 41-5/8” Minimum Mantel Width (OCV-RR-42) 47-5/8” Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 9: Chase Construction

    • Failure to prevent contact between insulation ceiling. This will help reduce heat loss from or other material and the chimney system the home around the fireplace. may cause overheating and fire. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 10: Framing The Fireplace

    Model OCV-RR-36 20-7/8 OCV-RR-42 20-7/8 *Header height to be adjusted for a raised floor beneath the fireplace **If interior of chase will be drywalled, add drywall thickness to dimension Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 11: Mount & Level The Fireplace

    • Overlap the strips by 1” minimum. • The metal strips must extend past the front and sides of the fireplace by 2 inches. (see figures 7.1 and 7.2) Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 12: Chimney Requirements

    Minimum height with offset 14 feet Maximum distance between chimney supports 8 feet Maximum height 40 feet Maximum unsupported chimney height above the roof 5 feet Maximum distance between elbows 72 inches Figure 9.1 Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 13: Optional Offset/Elbow Installation

    13 ¼” 51 ¼” 31 ¼” 48” + 12” 64 ¼” 16” 60” 34 ¼” 48” + 18” 70” 17 ½” 65 ¼” 37 ¼” 48” + 24” 75 ¾” 19” 70 ½” Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 14: Termination Requirements

    Continue installing the sections upwards using a minimum of three, #8 x ½” self-drilling screws per joint. Never use over-length screws that could penetrate the inner lining of the chimney.  The final chimney height should be determined using the specifications in Section 8 Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 15: Firestops

    A within the enclosure must maintain the required Firestop is not to be installed at the roof 2-inch air space to combustibles. penetration. Figure 11.1 Figure 12.1 Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 16: Complete The Top Termination

    Olympia Chimney and Venting is not responsible for discoloration, distortion, cracking, or other material failures of finishing materials due to heat or smoke. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 17: Hearth Extensions - Building & Finishing

    Refer to figure 16.1 for required dimensions. Model OCV-RR-36 35-5/8 51-5/8 OCV-RR-42 41-5/8 57-5/8 Minimum k per r per c per Material thickness inch inch inch required Durock 1.92 2.54 .500 in. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 18: Hearth Extension 4" Or More Below Fireplace Opening

    When building the platform, account for the thickness non-combustible finishing materials. Seal gaps between the hearth extension and the front of the fireplace with a bead of non- combustible sealant or grout. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 19: Fireplace Opening & Hearth Extensions Flush With The Floor

    When creating the platform, allow for the thickness of the non-combustible finishing material. See Figure 16.4 • Seal the gaps between the hearth extensions and the front of the fireplace with a bead of non-combustible sealant or grout. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 20: Mantel & Wall Protection

    The metal surfaces on the fireplace. • Choose finishing materials carefully! • The space between the metal face of the fireplace and the framing. • Where the non-combustible board is placed over metal surfaces. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 21: Gas Log Provision

    Installation Code, CAN/CGA-B149.1-M95 or the Propane Installation Code, CAN/CGA-B149.2-M95. • The gas log set MUST have a gas shut-off. • The refractory panel must be sealed around the pipe with fireplace mortar or non-combustible sealant(see Figure 17.1) Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 22: Gas Log Conversion

    9. Replace refractory panel & retaining clip. 10. Run gas line. 11. Repack insulation around pipe in between inner and outer shell of firebox. 12. Seal refractory around gas-line pipe with fireplace mortar or a non-combustible sealant. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 23: Assembling Loose Parts/Brackets

    Once in position and affixed, bend the flanges forward until they are parellel with the front face of the Fireplace. Insert the retaining pins into the holes located on the legs of the Log Grate. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 24: Replacement Firebox Components

    (Z FB36-1, Z FB36-2, etc…) (Z FIREBRICK = Whole uncut brick) (Z FIREBRICK = Whole uncut brick) 34. Optional Components Optional Components 36” Bi-Fold 42” Bi-Fold Fireplace Doors Fireplace Doors Fresh Air Kit (ZRRD36) (ZRRD42) (OCV-RR-FAI) Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 25: Chimney Components

    Elbow – 30° Elbow/Offset Support Vented Roof Flashing Firestop (VA-EL0830) (VA-ELS58) (VA-F08YY) (VA-FS08) Extended Roof Brace Roof Support Telescoping Pipe Storm Collar (VA-RB58) (VA-RS58) (VA-TEL08) (VA-SC08SS) Wall Support Extended Wall Support (VA-WS58) (VA-WSE58) Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 26: General Operating Parts

    Failure to operate fireplace according to operating instructions could cause fire or injury. a. Flue Damper Prior to lighting the fireplace, verify the damper is fully opened by looking up from the inside of the fire chamber. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 27: Glass Doors

    Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and flame may be drawn out of the fireplace opening. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 28: Creosote & Soot Formation

    38. Maintenance Procedures (Professional) It is important that the chimney system be checked and cleaned annually. This is for the safety of the homeowner and necessary to meet the warranty requirements of Ventis Class-A chimney pipe & Ventis Forever Firebox.
  • Page 29: Safety & Operating Information

    Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace. DO NOT: • Store flammable material close to the fireplace • Use flammable liquids such as gasoline or charcoal lighter fluid to start or “freshen up” a fire in this fireplace Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 30: Log Grate

    A closed damper overfires the fireplace and spills smoke and flames into the room. NOTE: When operating the fireplace with approved unvented gas logs, the damper must be in the fully closed position. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 31: Overfiring

    • Chimney connector or fireplace glowing • Chimney fire As a rule of thumb, maintain a flame that is below the top of the viewable area of the fireplace to prevent overfiring. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 32: Fuel

    Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 33: Seasoning Firewood

    Uncovered wood can absorb moisture from rain or snow, delaying the drying process. Avoid completely covering the ends and sides as this may trap moisture from the ground and obstruct air circulation. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 34: Lighting Instructions

    Replace if crumbling lighter fluid to start or “freshen up” a fire in this or otherwise deteriorated. fireplace NOTICE! For safe operation, only replace the refractory with panels supplied by Olympia Chimney & Venting. Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 35 THIS PAGE LEFT INTENTIONALLY BLANK Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...
  • Page 36 Olympia Chimney & Venting 600 Sanders Street Scranton, PA 18505 Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4...