vlan 201
fcoe vsan 201
vpc domain 5
peer-keepalive destination 172.25.182.103 source 172.25.182.104
vsan database
vsan 201
fcdomain fcid database
vsan 201 wwn 10:00:78:e3:b5:f6:b3:5d fcid 0xd90000 dynamic
vsan 1 wwn 50:00:40:21:02:f4:65:2b fcid 0x4c0000 dynamic
vsan 201 wwn 50:00:40:21:02:f4:65:2b fcid 0xd90001 dynamic
interface port-channel20
switchport mode trunk
vpc peer-link
spanning-tree port type network
interface port-channel104
switchport mode fex-fabric
fex associate 104
interface port-channel201
switchport mode trunk
vpc 201
switchport trunk native vlan 182
interface vfc1
bind interface port-channel201
no shutdown
vsan database
vsan 201 interface vfc1
vsan 201 interface fc1/32
interface fc1/32
no shutdown
interface Ethernet1/1
switchport mode fex-fabric
fex associate 104
channel-group 104
interface Ethernet1/2
switchport mode fex-fabric
fex associate 104