8-2. MODEM system
1 Connection layout
PC
MAX : 15 m
Register-1
Use Com1 port
2 PC Cable wiring
TE-3000S/4000F/4500F (Com1)
Pin No.
Signal name
3
SD/TXD
2
RD/RXD
7
RS/RTS
8
CS/CTS
1
CD/DCD
4
ER/DTR
6
DR/DSR
9
CI/RI
5
GND
8-3. PRINTER Connection
Three printers can be connected to TE-3000S/4000F/4500F.
Com1 ~ Com3 are used for ports.
1 Connection layout
Maimum connection number : Max. 3 printer
Note:The slip printer can be connected one unit only.
on-line
Register-2
R/J
R/J
— 33 —
Register-3
R/J
MODEM (DSUB25)
Pin No.
Signal name
2
SD
3
RD
4
RS
5
CS
8
CD
20
ER
6
DR
22
CI
7
GND
Register
R/J
Register-32
R/J
Slip
R/J