Download Print this page
DELTA DORE TYXAL Installation And User Manual
DELTA DORE TYXAL Installation And User Manual

DELTA DORE TYXAL Installation And User Manual

Infrared and microwave irhx detector

Advertisement

Quick Links

TECHNICAL
7
CHARACTERISTICS
- Field of application: Wireless alarm equipment
- Radio range outside: 200 to 300 m depending on the environment
- Radio frequencies: 434 and 868 MHz bands, class I (standard EN300220)
- 9.9 GHz microwave detector (standard EN300400 / Use in France only)
- Temperature of use: -10°C to +55°C
- Nominal operating temperature: -5°C to +35°C
- Long term storage temperatures above 30°C may damage the operation of the batteries
- Nominal detection range: 12 meters (transversal movement)
- Angular width: 90°
- 7.2V power supply: Two LS14500 lithium batteries (supplied)
- Stand-by mode consumption: 80 µA
- Consumption for transmission: 20 mA
- Autonomy in normal operation: > 2 years
- Protection index: IP30 - IK02
- Use: dry interior only
- Self-surveillance of the unit: Tamper alarm in the case of opening
- Unit dimensions: 73 x 124 x 60 mm
- Weight (with 2 lithium batteries): 150 g
Device complying with the requirements of the
R&TTE 1999/5/EC directives
Bonnemain - 35270 COMBOURG - France
E-mail : deltadore@deltadore.com
Because of changes in standards and equipment, the characteristics given in the text and
the illustrations in this document are not binding unless confirmed by Delta Dore.
DELTA DORE
TYXAL
Wireless alarm range
1
PRESENTATION
The IRHX detector is a detector that combi-
nes 2 movement detection technologies.
Its infrared (detects temperature) and micro-
wave (detects movement) technologies
make it highly immune to untimely detec-
tions by the infrared sensor.
This equipment analyses movement in its
detection zone and sends an alarm informa-
tion if an intrusion is detected.
The detection by the infrared sensor is
confirmed by the microwave detection.
The product is exclusively used for
indoor protection and is not recommen-
ded for the surveillance of a room with
large glass windows (veranda, etc.).
2
LOCATION
Installation precautions for detec-
ting intrusions correctly:
- The detector should preferably be positio-
ned in a corner.
- The detection field must be clear of any
obstacles (curtains, cupboard, etc.).
- The detector must not be pointed towards
an exterior point of entry (window),
- The detector must be installed at a height
of around 2.30 m from the floor,
- Prevent any source of moving heat near
the detector; do not place the detector in
front of a heat source (convector, chimney,
etc.).
- Place the detector at least 2 metres away
from a fluorescent light.
Infrared and microwave
IRHX detector
Installation and User Guide
Detector
Base
Test button
Closing screw
Contents
- a dual technology radio detector,
- installation and user Guide,
- two LS14500 lithium batteries (supplied),
- a packet of screws.
Installation at
a height of
2.2 to 2.4 m
from the floor
point of entry from outside
detector
convector
installed at least
1 m from a convector
Lens

Advertisement

loading

Summary of Contents for DELTA DORE TYXAL

  • Page 1 1 m from a convector Bonnemain - 35270 COMBOURG - France E-mail : deltadore@deltadore.com Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed by Delta Dore.
  • Page 2 Record the detector: MOUNTING - Press the TEST button on the detector. The control unit emits a beep when it is associated with the detector, its LED "1" comes on. Unscrew the closing Parts to drill This indicator will already be on if an ele- screw.