Dovre 325MF Installation Instructions And Operating Manual

Dovre 325MF Installation Instructions And Operating Manual

Advertisement

Quick Links

INSTALLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING
INSTALLATION INSTRUCTIONS AND OPERATING MANUAL
INSTALLATION ET MODE D'EMPLOI
EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG
INSTRUCCIONES DE INSTALACIÓN Y USO
325MF
KACHEL
STOVE
POELE
FEUERSTÄTTE
ESTUFA
03.27107.100 - 02/2013

Advertisement

Table of Contents
loading

Summary of Contents for Dovre 325MF

  • Page 1 INSTALLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING KACHEL STOVE INSTALLATION INSTRUCTIONS AND OPERATING MANUAL INSTALLATION ET MODE D’EMPLOI POELE FEUERSTÄTTE EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG INSTRUCCIONES DE INSTALACIÓN Y USO ESTUFA 325MF 03.27107.100 - 02/2013...
  • Page 2: Table Of Contents

    Removing ashes Fog and mist Solving problems Maintenance Chimney Cleaning and other regular maintenance activities Exchange parts 325MF Appendix 1: Technical Data Appendix 2: Dimensions Appendix 3: Distance from combustible material Appendix 4: Diagnostic diagram Index Subject to change because of technical improvements...
  • Page 3: Introduction

    The appliance is intended for use in a living room. It should be connected hermetically to a well- functioning chimney. that the 325MF wood stove has been produced in We advise you have the appliance installed by an accordance with EN 13240.
  • Page 4: Safety

    Safety Installation Please note: All safety regulations must be requirements complied with strictly. Please read carefully the instructions supplied General with the appliance for installation, use and maintenance, before using the appliance. The appliance must be connected tightly to a well- The appliance must be installed in accordance functioning chimney.
  • Page 5: Ventilation Of The Area

    A draught/vacuum of 15 - 20 Pa during normal Ventilation of the area operation is ideal. For good combustion, the stove needs air (oxygen). Starting from the flue spigot, the flue must run as This air is supplied via adjustable air inlets from the vertically as possible.
  • Page 6: Product Description

    material. 7. Primary air slide The rule of thumb for a single-walled tube is a 8. Riddling rod distance of 3x the diameter. If a lining shell is fitted around the tube, a distance of 1x the Features of the appliance diameter is permissible.
  • Page 7 Note the location of the removable parts, so e. Remove grid holder (2), the grate (6) and the that you can re-position the parts in the correct ash pan (7). place later on. Chamotte inner plates are ochrous on delivery. They insulate the combustion chamber, improving combustion and they can withstand burning anthracite coals.
  • Page 8: Preparing The Outside Air Connection

    Because of the distance to the (combustible) wall, the protection plate may not be removed in the back shield. 1. Apply supplied fibre glass sealing tape (3) measuring 10 x 3 mm to the contact surface of the connection collar (2). 2. Affix the connection collar to the top plate with the materials supplied.
  • Page 9: Installing And Connecting

    Fuel start burning brown coal briquettes. For lighting the fireplace, follow the instructions in The appliance 325MF is a multi fuel stove.. This stove the "Lighting" paragraph. is suitable for burning natural wood; sawn and split wood that is sufficiently dry. The appliance is also...
  • Page 10: Lighting

    Preferably use category A anthracite coal with a low ash content. Use the recommended size 12/22 or 20/30. For lighting the fireplace, follow the instructions in the "Lighting" paragraph. Lighting You can check whether the flue has sufficient draught by lighting a ball of paper above the baffle plate. A cold flue often has insufficient draught and consequently, some smoke may escape into the room instead of up the chimney.
  • Page 11: Burning Brown Coal Briquettes

    1. Slowly open the stove door. Compact stacking 2. Spread the charcoal evenly across the bottom of the stove base. 3. Place the brown coal briquettes on the charcoal bed. 4. Close the door. 5. Regularly remove ashes from the stove base by riddling the grate.
  • Page 12: Extinguishing The Fire

    Control the air supply with the secondary air inlet. The secondary air inlet not only supplies air to the fire but to the glass as well, so that it does not quickly become dirty. Open the primary air inlet for the time being if the air supply by the secondary air inlet is inadequate or if you want to fan the fire.
  • Page 13: Fog And Mist

    Fog and mist Fog and mist hinder the flow of flue gases through the flue. Smoke can blow back and cause a stench. If it is not strictly necessary, it is better not to use the stove in foggy and misty weather. Solving problems Refer to the appendix "Diagnostic diagram"...
  • Page 14: Cleaning Glass

    Checking fire-resistant inner plates Maintenance enamelled stove The fire-resistant inner plates are consumables and Never clean the stove while it is still hot. The most subject to wear . Check the fire-resistant inner plates effective way to clean the enamelled surface of the frequently and replace them when necessary.
  • Page 15: Exchange Parts 325Mf

    Check the appliance for air leaks. Close any chinks with stove sealant. Allow the sealant to harden fully before lighting the stove, as any moisture in the sealant will form bubbles, resulting in a new air leak. Exchange parts 325MF 09.20020.101 Pos. Part number Description Quantity 03.56332.000...
  • Page 16: Appendix 1: Technical Data

    Appendix 1: Technical Data Model 325MF 6kW Nominal output 6 kW Chimney connection (diameter) 125 mm Weight +/- 118 kg Brown coal Anthracite Fuel Wood briquettes coal Fuel property, max. length wood, max. 30 cm 3"-6"-7" 20-30 format fuel Mass flow of flue gases 4.1 g/s...
  • Page 17 Model 325MF 4.6kW Nominal output 4.6 kW Chimney connection (diameter) 125 mm Weight +/- 118 kg Brown coal Anthracite Fuel Wood briquettes coal Fuel property, max. length wood, max. 30 cm 3"-6"-7" 20-30 format fuel Mass flow of flue gases 4.9 g/s...
  • Page 18: Appendix 2: Dimensions

    Appendix 2: Dimensions 325MF Subject to change because of technical improvements...
  • Page 19 325MF (GB) Subject to change because of technical improvements...
  • Page 20: Appendix 3: Distance From Combustible Material

    Appendix 3: Distance from combustible material 325MF - Minimal distance in millimetres 09-20008-017 Protective (insulated) connection pipe Combustible material Incombustible material, thickness 100 mm Please note! To guarantee the flow of combustion air, when no outside air connection is provided, the distance from the outside air connection collar to the wall must be at least 20 mm.
  • Page 21 325MF - Dimensions of fireproof protective plate 09-20002-004 Minimal dimensions of fireproof protective plate A (mm) B (mm) Din 18891 Germany Finland Norway Subject to change because of technical improvements...
  • Page 22: Appendix 4: Diagnostic Diagram

    Appendix 4: Diagnostic diagram Problem Wood will not stay lit Gives off insufficient heat Smoke emissions into the room when adding wood Fire in stove is too intense, is hard to adjust Deposit on the glass Possible cause Possible solution A cold flue usually fails to create sufficient draught.
  • Page 23: Index

    Index Coal ash content Combustible material distance from Adding fuel Connection Adding wood dimensions smoke emissions into the room Connection collar for connection to chimney Air control Connection to chimney Air inlets at top Air leak Connection to supply of outside air Air supply for fire Control air supply Anthracite coal...
  • Page 24 Fireproof inner plates Lubricate warning Floors Maintenance bearing capacity chimney fire safety clean glass Flue cleaning the appliance maintenance enamel requirements fire-resistant inner plates Flue gas lubrication mass flow 16-17 sealing temperature 16-17 Mist, do not burn wood Fog, do not burn wood Fuel adding Nominal output...
  • Page 25 Softwood Solving problems 13, 22 Stacking logs Storing wood Stove window cleaner Suitable fuel Supply of outside air 5, 8 Sweep chimney Temperature 16-17 Unsuitable fuel Ventilation connect supply of outside air rule of thumb Ventilation louvre Vermiculite inner plates Walls fire safety Warning...

Table of Contents