6. Piping Diagrams

Th2
Th1
HEAT
EXCHANGER
(EVAPORATOR)
LOC.
Th1
Thermistor for indoor Air temperature
Th2
Thermistor for Evaporator pipe temperature
Th3
Thermistor for outdoor Air temperature
Th4
Thermistor for Condenser pipe Air temperature
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
ACCUMULATOR
COMPRESSOR
Description
- 44 -
CAPILLARY TUBE
HEAT
EXCHANGER
(CONDENSER)
REVERSING VALVE
PCB Connector
CN-IDAT
CN-IDPT
CN-ODT
Th4
Th3
Cooling
Heatig
LGE Internal Use Only