3.3 ELECTRICAL REQUIREMENTS

3.3.1 ELECTRICAL DATA (FOR 230/208V MODEL)
CAUTION
1. Do not use an extension cord with this unit.
2. When the unit is in the OFF position, the power supply to the
electrical controls is still energized.
3. Disconnect the power to the unit before servicing
the unit.
4. Remove the power cord from the wall receptacle.
5. Remove or turn off the protective device (fuses or circuit breaker).
Wirings including installation of the receptacle must comply with the
NEC and local codes, local regulations.
FUSE- Use a time-delay fuse or circuit breaker. Refer to the nameplate
for proper power supply requirements.

3.3.2 ELECTRICAL SAFETY

IMPORTANT GROUNDING INSTRUCTIONS
The air conditioner has a three-prong grounding plug on its power supply cord which must be plugged into properly grounded
three-prong wall receptacle for your protection against possible shock hazard.
FUSE – Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.
208, 230, and 208/230 VOLT UNITS
These units are equipped with a three-prong grounding plug on the power supply cord which must be plugged into a matching
properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not
present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and
ordinances.
NOTE: DO NOT USE AN EXTENSION CORD on 208, 230, and 208/230 Volt units.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
230/208 volt receptacle configuration
- 23 -
Tandem
15 A
Perpendicular
20 A
Large Tandem
30 A
LGE Internal Use Only