2. Piping Diagrams

Indoor Unit
Heat
Exchanger
(Evaporator)
LOC.
Th1
Thermistor for indoor air temperature
Th2
Thermistor for evaporating temperature
Th3
Th4
Thermistor for outdoor air temperature
Th5
Thermistor for condensing temperature
Th6
Thermistor for discharge pipe temperature
Th7
Thermistor for suction pipe temperature
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Get user manuals:
See SafeManuals.com
Liquid Side
2-Way Valve
Th2
Th1
Th3
Gas Side
3-Way Valve
Description
Outdoor Unit
EEV
Accumulator
Th7
Compressor
PCB Connector
CN_TH1(INDOOR)
CN_TH2(INDOOR)
CN_TH3(INDOOR)
CN_TH2(OUTDOOR)
CN_TH3(OUTDOOR)
- 3 -
Heat
Exchanger
(Condenser)
Th4
Th5
Reversing Valve
Th6
Cooling
Heating