NC-3000 is AC 220V~240V, 60 Hz. Keep NC-3000 away from magnets, activated cellular phones, electrical appliances, or speakers within 13 cm / 5 inch. Contact Information Masterwork Automodules Tech Corp Ltd Address: 11F-3, 3, Yuanqu St.Nangang Taipei 11503...
Chapter 2. Overview of NC-3000 NC-3000 at a Glance ..................6 Overview of Control Panel ................7 Overview of LCD Display .................. 7...
NC-3000 at a Glance Hopper Guide Hopper 2.8 LCD Display Stacker Pocket Power Switch Serial Port Power Socket Printer SD Card Upgrade Socket PC Connection Socket Remote Display Socket Masterwork Automodules Tech Corp Ltd...
Overview of Control Panel Navigation Keys Number / Direction / Start (Clear) Keys 2.8” LCD Display Overview of LCD Display Auto / Manual Operation Add Mode Counting Speed Counting Mode Batch Currency Detection Information Counting modes Counting Result Print Overview of NC-3000...
Power On / Off To Switch on NC-3000: Plug in the power cord to the device. Press the Power Switch button on the back side of the device. After the system runs, NC3000 enters main display. To Switch off NC-3000 Confirm that all the counting results are saved ...
On M (Manual Start Mode), the device counts after pressing the Start. Auto Mode Manual Mode Add mode To sum up the counting result. Press the key Function and Add (5) to toggle between Add On/Off Mode. Masterwork Automodules Tech Corp Ltd...
When Add mode is turned on, the counting results of different bundles are accumulated automatically. The display shows the current status of the mode, the " " icon lights up if Add mode is on, and disappears when Add mode is off. Add Mode On Add Mode Off Counting Speed...
Result Display Modes and Clearing The counting result is shown on the display according to the mode selected below: ○ To choose a display mode, press the navigation key " (Info) ", and the result shows: Amount and Quantity mode – value of notes counted, and number of notes counted.
Press the C to cancel the operation. Printing receipt. Receipt included local value, exchange rate could be set, please refer to p.24. Printer Connected Print Dialogue Masterwork Automodules Tech Corp Ltd...
Go back to main screen. anytime to delete last input operation and return to the Press C upper layer, until the main screen. Settings Menu 1st Page Settings Menu 2nd Page Masterwork Automodules Tech Corp Ltd...
Contents and Functions of the Environment Settings Following options are available: Contrast Adjust Highlight the icon. press the " (Enter)" Adjust the LCD panel contrast. Light to Dark, 7 levels (default is level 4). Backlight Setting Highlight the icon.
On / Off (default is ON) Turn key sound on or off. Use the “ ” and “ ” to toggle a desired mode. Confirm setting. " (Enter)"or "Start" press the to confirm the setting Masterwork Automodules Tech Corp Ltd...
Set the Currency Exchange Rates Highlight the icon. press the " (Enter)" Highlight the desired currency by the navigation keys " (Move Up)", " (Move Down)". Press " (Enter) " to set the rate. The currency exchange table can be set up to six ...
Select the paper size of the connected thermal printer. the “ ” and “ ” to toggle a desired setting Confirm setting. Press the to confirm setting and go back to upper layer. Masterwork Automodules Tech Corp Ltd...
(Move Right)" to switch between MG / IR options. Input the number from 1~9 to set the desired sensibility. Confirm setting. "Start" press the to confirm the setting and back to upper level Masterwork Automodules Tech Corp Ltd...
Wipe the bill path and the sensor surface again; do not let any liquid drip into the device. *NOTE: Avoid spraying cleaner directly on the device, and be sure to day the bill path before closing it. Masterwork Automodules Tech Corp Ltd...
After complete the calibration of white slip, install the black slip and repeat the step 2~3 until the display shows "OK", Once you completed the calibration, just turn the unit off, NC-3000 Series runs in normal mode the next time you turn it on.
The motor starts to run at different speeds for calibration. Wait till the motor stops and display shows OK. Once you completed the calibration, just turn the unit off, NC-3000 Series runs in normal mode the next time you turn it on. Motor Calibration Menu...
Appendix. Specification Feed System Roller friction system Counterfeit Detection IR, MG, UV (OPTION), Color (OPTION) 900/1200/1500 notes/min Counting Speed Available Currencies USD, EUR, LOCAL (OPTION) Hopper Capacity Max. 500 notes Pocket Capacity Max. 200 notes Countable Note Size 60 X 85 X 0.08mm ~ 100 X 190 X 0.12mm Display 2.8 Inch LCD Power supply...