Refrigeration Cycle; Condenser; Evaporator; Capillary Tube - LG 230/208V Service Manual

Lg service manual room air conditioner
Hide thumbs Also See for 230/208V:
Table of Contents

Advertisement

2.4 REFRIGERATION CYCLE

CAUTION
Discharge the refrigerant system using Freon
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before
venting the Freon
TM
after servicing the system.

2.4.1 CONDENSER

1. Remove the brace and the shroud.
(Refer to section 2.2.2)
2. Remove the 4 screws which fasten the shroud.
(Refer to section 2.2.2)
3. Push forward the shroud and remove the 2 screws
which fasten the condenser with the basepan.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
5. Remove the condenser.
6. Re-install the components by referring to notes.
(See Fig. 14)

2.4.2 EVAPORATOR

1. Remove the front grille. (Refer to section 2.1.1)
2. Discharge the refrigerant completely.
3. Remove the control box assembly.
(Refer to section 2.1.2)
4. Remove the 4 screws which fasten the evaporator
at the left side and the right side.
5. Move the evaporator sideward carefully and then
unbraze the interconnecting tube at the evaporator
connectors.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Fig. 15)

2.4.3 CAPILLARY TUBE

1. After discharging the refrigerant completely,
unbraze the interconnecting tube at the capillary
tube.
2. Remove the capillary tube.
3. Re-install the components by referring to notes.
. Leave the valve in place
TM
Figure 14
Figure 15
Figure 15
—14—

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp120cemLp090hem

Table of Contents