Ozone Solutions OMZ-2500 User Manual page 2

Ozone generator

Advertisement

Read complete instructions before using ozone generator
PLACEMENT AND SETTING OF MACHINE
1. The OMZ-2500 is designed for universal application. This unit can be utilized as a portable
service unit, or as a stationary air purifier unit.
2 a. The OMZ-2500 controls feature an on/off switch powering the unit and fan and a variable
ozone dial. Ozone production begins when both the variable ozone dial and main switch is
turned ON.
2 b. (Setting Ozone Level) The right level is when all the generated ozone is being used up
accomplishing its job. However, this is difficult to obtain because it becomes a balancing act.
Initially the unit output is set high to get rid of the problem odor as quickly as possible. As this is
being accomplished less ozone is required for the diminishing odors, thereby leaving some
residual ozone in the air. If the unit output is not turned down, eventually a high ozone residual
may occur. If there is a heavy smell of ozone, then there is more ozone present than is required
to do the job. Simply turn the variable ozone dial down. The levels of ozone required to clean
most environments are from 0.03 ppm to 0.10 ppm. This does not apply to shock treatment. If
a room requires shock treatment, turn the unit on high and ensure no humans or pets are in the
room. Fish are okay.
Under heavy duty use or severely polluted areas, The OMZ-2500 should be inspected every 3
to 4 weeks for fine dust or oily residue collecting on generator surfaces or plates. Clean the
particle filters using compressed air on the side of the unit by removing the retainer ring every 4
weeks. Light duty use requires cleaning every 4 weeks to 6 months depending on the severity
of pollution and the humidity level.
OZONE GENERATOR PLATE CLEANING INSTRUCTIONS
WARNING: HIGH VOLTAGE!
before starting any maintenance procedure or electrical shock injury may
Figure 1
MAINTENANCE
Ensure that power supply is disconnected
result.
Ensure that the unit is unplugged
before servicing!
1. Locate and remove four screws from the top and
bottom of the unit. Be very careful not to strip the screw
holes when putting the screws back in. (Figure 1)
2. Gently slide out the generator chassis out from the
PVC case (Figure 2+3).