5 Hardware Interface

5.1.3 Trigger and Strobe Signals

The power connector contains an external trigger input and a strobe output.
The trigger input is equipped with a constant current diode which limits the
current of the optocoupler over a wide range of voltages. Trigger signals can
thus directly get connected with the input pin and there is no need for a current
limiting resistor, that depends with its value on the input voltage. The input
voltage to the TRIGGER pin must not exceed +15V DC, to avoid damage to the
internal ESD protection and the optocoupler!
In order to use the strobe output, the internal optocoupler must be powered with 5 .. 15 V DC.
The STROBE signal is an open-collector output, therefore, the user must connect a pull-up
resistor (see Table 5.1) to STROBE_VDD (5 .. 15 V DC) as shown in Fig. 5.2. This resistor should be
located directly at the signal receiver.
Figure 5.2: Circuit for the trigger input signals
The maximum sink current of the STROBE pin is 8 mA. Do not connect inductive
or capacitive loads, such loads may result in damage of the optocoupler! If the
application requires this, please use voltage suppressor diodes in parallel with
this components to protect the optocoupler.