2 How to get started (CameraLink
The sensor has no cover glass, therefore dust on the sensor surface may resemble
to clusters or extended regions of dead pixel.
To choose a lens,
www.photonfocus.com.
5.
Connect the camera to the frame grabber with a suitable CameraLink
®
CameraLink
cables can be purchased from Photonfocus directly (www.photonfocus.com).
Please note that Photonfocus provides appropriate solutions for your advanced vision
applications.
Figure 2.2: Camera with frame grabber, power supply and cable.
Do not connect or disconnect the CameraLink
For more information about CameraLink
6.
Connect a suitable power supply to the provided 7-pole power plug. For the connector
assembly see Fig. A.1. The pinout of the connector is shown in Appendix A.
Check the correct supply voltage and polarity! Do not exceed the maximum
operating voltage of +12V DC (± 10%).
7.
Connect the power supply to the camera (see Fig. 2.2).

The status LED on the rear of the camera will light red for a short moment, and
then flash green. For more information see Section 5.1.4.