PERFORMANCE DATA SHEET

Model
Rated Service Flow (gpm)
Pressure Drop at Rated Service
Flow Rate (psid)
Rated Capacity
(grains @ lb of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum Flow Rate During
Regeneration (gpm)
Indion 225 NaF Ion Exchange
Resin (cu ft)
Tank size
Backwash - gpm
Rapid Rinse/purge - gpm
Operating Pressure: 20 -125 psi or 1.4 – 8.6 bar, Operating Temperature: 35 - 100° F or 1.7 – 38° C
Acceptable Salt Type: Sodium Chloride – Block, Pellet or coarse solar salt
All Systems above tested at 35 psi +/- 5 psi, pH of 7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of the rated service flow rate for
the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44
for specific performance claims as verified and substantiated by test data. The rated salt
efficiencies above were also determined in accordance with NSF/ANSI 44 and are only valid
at the salt dosage referenced above. An efficiency rated water softener is a demand initiated
regeneration (DIR) softener which also complies with specific performance specifications
intended to minimize the amount of regenerant brine and water used in its operation. Efficiency
rated water softeners shall have a rated salt efficiency of not less that 3350 grains of total
hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total
hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating.
The rated efficiency of the water softener, the salt dosage at that efficiency, the capacity at
that salt dosage and that of the efficiency is only valid at the stated salt dosage. Efficiency is
measured by a laboratory test described in NSF/ANSI 44. The test represents the maximum
possible efficiency the system can achieve. Operational efficiency is the actual efficiency
achieved after the system has been installed. It is typically less than the efficiency due to
individual application factors including water hardness, water usage, and other contaminants
that reduce the water softener's capacity. These systems are not intended to be used
for treating water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system. Refer to the system Installation and Service Manuals
for set-up and programming instructions.Contact OMNIFILTER for parts and service. See your
owners manual for warranty information.Important Notice: For conditions of use, health claims
certified by the California Department of Public Health and replacement parts, see product data
sheet .
Iowa Requirement:
Seller: ________________________________________________ Date:
_________________________
Buyer: ________________________________________________ Date:
_________________________
10/20/11
22 • DE11 OM26KCS, OM32KCS, OM36KCS
OM26KCS
8 .0
10 .0
11,755 @ 2.7
21,905 @ 8.5
26,815 @ 13.15
4,341/lb salt @ 2.7 lbs
2 .1
0 .82
9" x 35"
2 .1
2 .1
OMNI FILTER
293 Wright Street
Delavan, WI 53115
PH: (800) 937-6664
OM32KCS
10 .0
12 .0
14,125 @ 3.3
26,321 @ 10.4
32,221 @ 16.0
4,278/lb salt @ 3.3 lbs
2 .7
1 .0
10" x 35"
2 .7
2 .7
OM36KCS
11 .0
15
15,821 @ 3.6
29,481 @ 11.3
36,089 @ 17.5
4,396/lb salt @ 3.6 lbs
2 .7
1 .09
10" x 35"
2 .7
2 .7
Tested and Certified by the
WQA against NSF/ANSI
Standard 44 for softener
performance for "lead free"
compliance.