WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Feed 6" of power cable through the knockout
opening and secure cable to the wiring box
with an appropriate connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.

CONNECT DUCTWORK

Ducted Configuration
1. Use screws and wall anchors to secure
upper bracket to the ceiling and wall as
shown.
2. Use 6" round metal duct (8" for K42) to
connect the duct collar on the hood to the
ductwork above.
3. Use duct tape to make all joints secure and
air tight.
4. Connect the upper section of decorative flue
to the bracket with screws provided.
5. Slide the lower section of decorative flue
downward, until it fits properly around hood.
6. Secure decorative flue to hood with screws
provided.
FASTEN
FLUE TO
HOOD & UPPER
BRACKET WITH
SCREWS
WIRING BOX
COVER
UPPER
BRACKET
- 4 -
DUCT
COLLAR
FASTEN
UPPER
BRACKET
TO CEILING &
WALL WITH
SCREWS (&
ANCHORS IF
NECESSARY)
DECORATIVE
FLUE
DUCT TAPE
AIR VENT
POSITION FOR
DUCTED
CONFIGURATION
6" ROUND
METAL DUCT
(8" for K42)