Installation & Servicing Instructions - Nu-Flame N1 Use & Maintenance Instructions

Evolution plus gas effect fires (natural gas & lpg)
Table of Contents

Advertisement

PLACE OF PURCHASE ..............................................................................................
ADDRESS & TEL. NO. ................................................................................................................................................
..................................................................................................................................................................................
..................................................................................................................................................................................
APPLIANCE SERIAL NO. ..............................................
INSTALLED BY ................................................................................
INSTALLATION & SERVICING INSTRUCTIONS
FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES
NATURAL GAS MODELS: N1, N1I, N2R, N2, N2I, N3R, N3, N3I, N4R, N4, N4I, N5R, N5, N5I & N6
THIS APPLIANCE MUST BE INSTALLED & SERVICED BY A PROPERLY QUALIFIED
(IN ACCORDANCE WITH LOCAL & NATIONAL CODES) INSTALLATION ENGINEER.
IMPORTANT:
BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY. THESE INSTRUCTIONS
SHOULD BE KEPT IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING DETAILS.
PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE AS STATED ON THE APPLIANCE DATA
SIMULATED COALS, SIMULATED PEBBLES, SIMULATED LOGS OR SIMULATED DRIFTWOOD, MANUFACTURED FROM
REFRACTORY FIBRE, ARE SUPPLIED WITH THIS APPLIANCE. DO NOT USE REAL COALS, PEBBLES, LOGS OR
DRIFTWOOD, AS THIS IS DANGEROUS. IF THE SIMULATED COALS, SIMULATED PEBBLES, SIMULATED LOGS OR
SIMULATED DRIFTWOOD NEED RENEWING PLEASE OBTAIN SUITABLE REPLACEMENTS FROM A NU-FLAME
GAS TYPE: SEE DATA PLATE.
BURNER: NU-FLAME EVOLUTION PLUS STAINLESS STEEL
FLAME SAFETY: OXYGEN DEPLETION & FLAME FAILURE DEVICE STANDARD TO ALL MODELS.
APPLIANCE INLET WORKING PRESSURE: SEE DATA PLATE.
IGNITION: PIEZO.
INLET CONNECTION: 8MM COMPRESSION FITTING.
NETT HEAT INPUT: SEE DATA PLATE.
®
RECORD DATA TO BE COMPLETED & KEPT BY USER:
(NATURAL GAS & LPG)
FOR DECORATIVE PURPOSES ONLY
LPG MODELS: L1, L2R, L2, L3R, L3, L4R, L4, L5 & L6
APPLIANCE DATA
PLATE.
STOCKIST.
Page 2 of 10
DATE ..........................
GAS SAFE. NO ...................................