Advertisement

Quick Links

i - S E R I E S
a d v a n c E d a m p l I f I E R S
iD4
INFORMATION FOR USE
i - S E R I E S
TDA302USERGBC
Revision C, 2013-10-01
Please visit our website www.camcoaudio.com for the latest version of this user manual. Please note that the leading version of CAMCO manuals is always the English one.
© Copyright 2013 by CAMCO Produktions- und Vertriebs-GmbH
für Beschallungs- und Beleuchtungsanlagen
Fischpicke 5, D-57482 Wenden, Germany
Telephone +49 (0) 2762 / 408-0
P.1
USER MANUAL
i - S E R I E S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iD4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Camco iD4

  • Page 1 TDA302USERGBC Revision C, 2013-10-01 Please visit our website www.camcoaudio.com for the latest version of this user manual. Please note that the leading version of CAMCO manuals is always the English one. © Copyright 2013 by CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen...
  • Page 2 The disconnection device from mains (mains plug or external all-pole circuit breaker) shall remain readily operable and freely accessible The iD4 amplifier is designed for the amplification of pulsed audio sig- at all times. nals. The amplifier should only be connected to speakers with an average impedance as indicated.
  • Page 3 17. Packaging and shipping if liquid has been spilled or objects have fallen into the amplifier When shipping the iD4 amplifier, always use the original shipping carton if the amplifier has been exposed to rain or moisture and packing materials. For maximum protection repack the unit as it was if the amplifier has been dropped or damaged in any other way originally packed at the factory.
  • Page 4: Explanation Of Symbols

    i - S E R I E S a d v a n c E d a m p l I f I E R S ExplANATION OF SyMBOlS CAUTION – HIGH VOlTAGE HAZARDS CAUTION ExIST WITHIN THIS pRODUCT. RISK OF ElECTRIC SHOCK REFER All SERVICING TO DO NOT OpEN AUTHORIZED pERSONNEl.
  • Page 5 CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Manufacturer´s Address: Fischpicke 5, D-57482 Wenden, Germany Declares that the product with the model name: CAMCO Power amplifier iD4 Conforms to the following standards: EN60065 Safety EN55103-1 Emission EN55103-2 Immunity The operating conditions and application environments presupposed in the information for use (user manual) are to be kept accordingly.
  • Page 6: Table Of Contents

    P.16 1.1 Unpacking 4.5.1 Inrush Current Limitation P.16 2. The Amplifier 4.5.2 Mains Over Voltage Detection P.16 2.1 iD4 – The Front 4.5.3 Mains Surge Overvoltage Protection P.16 2.2 iD4 – The Rear 4.5.4 Mains Failure Detection P.16 3. Installation 4.5.5 Fuse Protection...
  • Page 7: Welcome To Camco

    The CAMCO peace of mind long term manufactures warranty is our com- When shipping the iD4 amplifier, always use the original shipping carton mitment to you that every CAMCO amplifier is ready to give you many and packing materials. For maximum protection, repack the unit as it was years of faultless service.
  • Page 8: The Amplifier

    1× 4 500 W mono bridge @ 8 Ω peak 1× 3 800 W mono bridge @ 8 Ω The iD4 has been designed as a powerful two channel amplifier with on- board 64 bit DSP processing. Both amplifier settings and DSP settings 1× 3 000 W mono bridge @ 4 Ω...
  • Page 9: Id4 - The Front

    E d a m p l I f I E R S Œ  Ž   “ ” ‘ ’ • 2.1 iD4 – The Front 2.2 iD4 – The Rear Signal-LEDs XLR – line input 1 Œ Clip-LEDs XLR – line input 2  Ž...
  • Page 10: Installation

    During power up the Clip- and Signal-LEDs from both channels Only connect the iD4 amplifier to an appropriate AC circuit and outlet, will light up in red for a few seconds. To turn the amplifier off, press on the according to the requirements indicated in the second line on the rating lower part of the switch.
  • Page 11: Mounting

    i - S E R I E S a d v a n c E d a m p l I f I E R S 3.3 Mounting 3.4 Cooling Use four screws and washers when mounting the amplifier to the front rack The air is taken in from the front and out through the back.
  • Page 12: Signal Inputs

    DSP presets. vol tages that are potentially life threatening. The iD4 is configured by default to use DHCP for automatic IP address Wiring to these terminals requires installation by an instructed person or assignment in the network. If not desired, this feature can be set through the use of ready-made leads or cords.
  • Page 13: Dual Channel Operation

    i - S E R I E S a d v a n c E d a m p l I f I E R S 3.7.2 Dual Channel Operation ! WARNING! Two fully independent amplifier channels (“Stereo” – normal operating In Mono Bridge Operation RMS output voltages can be as high as mode).
  • Page 14: Operation

    i - S E R I E S a d v a n c E d a m p l I f I E R S 4. Operation cates heavy clipping. These LED’s exclusively indicate hardware clipping of the power amplifier stage. Possible internal DSP limitation and compres- 4.1 User Interface Elements sion is not indicated here.
  • Page 15: Menu Buttons

    An additional feature is the automatic standby function which will set the work in a round-robin fashion, regardless of the rotation direction. iD4 in standby mode if no input signal (analogue and / or AES) is applied for a certain period of time. This delay time can be set individually (or...
  • Page 16: Power Amp Protection Systems

    4.5.3 Mains Surge Overvoltage Protection of the outputs, the corresponding channel will be muted. If DC The iD4 is fitted with a varistor unit, protecting the SMPS from sporadic was only detected for a short moment, the amplifier will release surge overvoltages coming from the mains distribution.
  • Page 17: Fuse Protection

    E d a m p l I f I E R S 4.5.5 Fuse Protection 4.6 Main SMPS Protections When driving the iD4 at very high output levels over a longer period of time (i.e. several seconds and minutes) the average mains current draw can 4.6.1 Over Current Protection become very high.
  • Page 18: Filter Cleaning

    4.8 Filter Cleaning ! WARNING! The air intake on the front of your iD4 amplifier is fitted with a removable Turn off and disconnect the amplifier from the mains before removing filter system. If the filter becomes clogged, the unit will not cool as effi- the front frame.
  • Page 19: Troubleshooting

    i - S E R I E S a d v a n c E d a m p l I f I E R S 5. Troubleshooting 5.1 Problem: No reaction when switching the amplifier on If nothing happens when switching the amplifier on (i.e. the display stays totally dark, no message inside the display), please check following points: Check mains cable and plug Confirm that the AC outlet works by plugging in any other device...
  • Page 20: Specification

    i - S E R I E S a d v a n c E d a m p l I f I E R S 6. Specification Output power 2 × 600 W @ 16 Ω 1 kHz, THD ≤ 1%, in dual channel operation 2 ×...
  • Page 21 i - S E R I E S a d v a n c E d a m p l I f I E R S Frequency response 10 Hz – 20 kHz: ± 0,175 dB @ 4 Ω load with 120 W ouptut power THD+N over frequency 20 Hz –...
  • Page 22 i - S E R I E S a d v a n c E d a m p l I f I E R S Latency Min. 0,58 ms Digital inputs AES / EBU, 16 to 24 bit, 44,1, 48, 88,2, or 96 kHz AC mains 230 V AC, 50 / 60 Hz (for Europe), 190 –...
  • Page 23: Typical Performance Diagrams

    i - S E R I E S a d v a n c E d a m p l I f I E R S 7. Typical Performance Diagrams +0,5 -0,5 -1,5 0,01 -2,5 -3,5 0,001 Figure 7.1 Figure 7.3 Gain vs.
  • Page 24 i - S E R I E S a d v a n c E d a m p l I f I E R S -100 -120 Figure 7.5 Figure 7.7 Channel separation vs. frequency @ 120 W / 4 Ω Common mode rejection ratio vs. frequency (Measurement of a typical performance of Ch 1 Ch 2 &...
  • Page 25 i - S E R I E S a d v a n c E d a m p l I f I E R S 300 m 1000 100 m 10 m Figure 7.9 Figure 7.10 Output impedance vs. frequency Damping factor into 8 Ω...
  • Page 26: Unit Conversion Equations And Lookup Table

    3 600,0 7 200,0 424,33 45,74 43,52 2 812,5 5 625,0 11 250,0 Values in grey are calculated only. The iD4 is not able to deliver these output powers. P.26 USER MANUAL i - S E R I E S...
  • Page 27: Warranty Information

    9.1 Summary of Warranty All components must be shipped in the original packaging. CAMCO guarantees the iD4 amplifier to be free from defective material and / or workmanship for a period of six (6) years from the date of sale.
  • Page 28: Service Information

    If the warranty has expired, payment will be: Cash / Cheque VISA MasterCard Our web site: www.camcoaudio.com provides a complete list of CAMCO dealers / distributors. Shipping Address To transport the amplifier, the original packing materials must be used. CAMCO produktions- und Vertriebs-GmbH für Beschallungs-...
  • Page 29: Maintenance Information

    i - S E R I E S a d v a n c E d a m p l I f I E R S 11. Maintenance Information 12. Decommissioning Cleaning and servicing the inside of the amplifier must never be carried out During the decommissioning process of the amplifier, all legally prescribed by unqualified personnel.
  • Page 30: Company Information

    - S E R I E S a d v a n c E d a m p l I f I E R S 13. Company Information Mailing Address: CAMCO Produktions- und Vertriebs-GmbH für Beschallungs- und Beleuchtungsanlagen Fischpicke 5 57482 Wenden...
  • Page 31: Changes Made To The Amplifier / Notices

    i - S E R I E S a d v a n c E d a m p l I f I E R S 14. Changes Made to The Amplifier / Notices l NOTE / IMpORTANT: Please consider that any changes made to the amplifier have to be docu- mentated in writing and passed on to the buyer in the event of resale! P.31 USER MANUAL...
  • Page 32 i - S E R I E S a d v a n c E d a m p l I f I E R S P.32 USER MANUAL i - S E R I E S...

Table of Contents