grease lubricated; Vibrator-oil bath lubricated
Acoustic Noise (According to 2000/14/EC)
Model No.:
Measured Sound power Level
Guaranteed sound power level
Uncertainty
Hand-Arm-Vibration (as per ISO8662,part 1,m/s
Name Plate:
Working Size: (LXWXH):108x35x85 cm
SYMPTOM
Travel Speed too low, and
vibration is weak
SP-60A
105.48dB(A)
105dB
2.5dB
2
):4-9
TROUBLE SHOOTING
POSSIBLE CAUSES
Engine speed too low?
Clutch slips?
TRANSPORTATION
1.
Always shut off engine when transporting machine.
2.
Make sure lifting device has enough capacity to hold
machine (see identification plate on machine for weight).
3.
Use central lifting point (a)when lifting machine.
4.
Trolley wheel (b) is used for short distance transportation.
SOLUTION
Set engine speed to correct RPM.
Check or replace clutch