Warning: Power supply voltage
Connecting this product to a voltage
supply greater than the specified
maximum rating may cause permanent
damage to the unit. Refer to the Technical
specification section for voltage rating.
Warning: Product grounding
Before applying power to this product,
ensure it has been correctly grounded, in
accordance with the instructions provided.
Grounding — Dedicated drain wire
The power cable supplied with this product includes
a dedicated shield (drain) wire for connection to a
vessel's RF ground point.
It is important that an effective RF ground is
connected to the system. A single ground point
should be used for all equipment. The unit can be
grounded by connecting the shield (drain) wire of
the power cable to the vessel's RF ground point.
On vessels without an RF ground system the shield
(drain) wire should be connected directly to the
negative battery terminal.
The dc power system should be either:
• Negative grounded, with the negative battery
terminal connected to the vessel's ground.
• Floating, with neither battery terminal connected
to the vessel's ground
Warning: Positive ground systems
Do not connect this unit to a system which
has positive grounding.
Breakers, fuses and circuit protection
The information below is provided as guidance
to help protect your product. The example
illustrations provided are for common vessel power
arrangements, if you are unsure how to provide the
correct level of protection then please consult a
Raymarine authorized dealer for support.
Distribution panel connection
It is recommended that your product is wired through
your vessel's distribution panel via a thermal breaker
or fuse.
1
4
6
1. Vessel power supply positive (+)
2. In-line fuse. (If your products power cable does
not have an in-line fuse then an one fuse should
be fitted.)
Cables and connections
5
7
D13017-1
3. Product power cable
4. Vessel power supply negative (-)
5. * Drain wire
6. Vessel distribution panel
7. Vessel RF ground point connection
Battery connection with RF ground
If your vessel does not have a distribution panel then
your product may be wired directly to the battery with
the drain wire connected to the vessel's RF ground
point.
1
6
1. Vessel power supply positive (+)
2. Vessel power supply negative (-)
3. In-line fuse (If your products power cable does
not have a built in fuse then an in-line fuse
should be fitted.)
4. * Drain wire
5. Product power cable
6. Vessel battery
7. Vessel RF ground point connection
Battery connection with no RF ground
If your vessel does not have a distribution panel
or an RF ground point then your product may be
wired directly to the battery with the drain wire also
connected to the battery's negative terminal.
1
6
1. Vessel power supply positive (+)
2. Vessel power supply negative (-)
3. In-line fuse (If your products power cable does
not have a built in fuse then an in-line fuse
should be fitted.)
4. Drain wire connected to vessel negative power
supply.
5. Product power cable
6. Vessel battery
In-line fuse and thermal breaker ratings
The following in-line fuse and thermal breaker ratings
apply to your product:
In-line fuse rating
2 A slow blow
3
7
3
Thermal breaker rating
3 A (if only connecting one
device)
D13018-1
D13019-1