Installation And Draft Considerations - Heatilator CONSTITUTION Installation & Operating Instructions Manual

Epa certified woodburning fireplace
Table of Contents

Advertisement

Constitution
EPA Certified Fireplace
The Constitution Fireplace requires a minimum flue draft of -0.10 inches of water column on High, and -0.04 inches
of water column on Low, as measured with a draft meter. Most dealers have draft meters available to measure your
flue draft if you suspect a problem.
If the fire is difficult to start, and smoke spills out of the door, or you find it hard to establish and maintain a moderately high
burn rate, then the flue draft is too low and corrective measures must be taken.
Recommended
NOTE: The outside air kit is installed on the right hand side of the fireplace.
1. Cut a 6" hole in outside wall to accommodate outside
air piping.
2. Use 6" metal flex or rigid piping (not supplied) to directly
connect outside air to fireplace intake. Secure with
hose clamp.
3. Use the supplied termination cap with a rodent screen.
4. Seal between the wall and the pipe with silicone to
prevent moisture penetration.
NOTE: A control knob allows you control of the outside
air inlet. Use of outside air for combustion is required to
conserve heated air within the structure and to provide make
up air to keep the fireplace venting properly.
IMPORTANT!!
OUTSIDE AIR MUST BE IN OPEN POSITION TO OPERATE FIREPLACE PROPERLY
480-1091

INSTALLATION AND DRAFT CONSIDERATIONS

Location
Not
Marginal
Recommended
Location
Location
2nd Floor
Balcony
1st Floor
Cathedral Ceiling Construction
OUTSIDE AIR KIT INSTALLATION
Recommended
Location
Multi-level Roofs
4
Location NOT
Recommended
4-03

Advertisement

Table of Contents
loading

Table of Contents