Burning Process; Air Control - Heatilator CONSTITUTION Installation & Operating Instructions Manual

Epa certified woodburning fireplace
Table of Contents

Advertisement

Constitution
EPA Certified Fireplace

3. Burning Process

Fire requires three things to burn: fuel, air and heat.
So, if heat is robbed from the fireplace during the
drying stage, the new load of wood has reduced the
chances for a good clean burn. For this reason, it
is always best to burn dry, seasoned firewood. We
do not advise burning unseasoned wood, however if it
happens, you must open the Slide Air Control and burn
the fireplace at a high burn setting for a longer time to
start it burning.
Kindling or 1st stage:
It helps to know a little about the actual process of
burning in order to understand what goes on inside a
fireplace. The first stage of burning is called the kindling
stage. In this stage, the wood is heated to a temperature
high enough to evaporate the moisture which is present
in all wood. The wood will reach the boiling point of
water (212°F) and will not get any hotter until the water
is evaporated. This process takes heat from the coals
and tends to cool the fireplace.
2nd stage:
The next stage of burning, the secondary stage, is the
period when the wood gives off flammable gases which
burn above the fuel with bright flames. During this
stage of burning it is very important that the flames be
maintained and not allowed to go out. This will ensure
the cleanest possible fire. If you are adjusting your
fireplace for a low burn rate, you should close down the
air to the point where you can still maintain some flame.
If the flames tend to go out, the fireplace is set too low
for your burning conditions.
Final stage:
The final stage of burning is the charcoal stage. This
occurs when the flammable gases have been mostly
burned and only charcoal remains. This is a naturally
clean portion of the burn. The coals burn with hot
blue flames.
It is very important to reload your fireplace while enough
lively hot coals remain in order to provide the amount
of heat needed to dry and rekindle the next load of
wood. It is best to open the air control for a short while
before reloading. This livens up the coalbed. Open
door slowly so that ash or smoke does not exit fireplace
through opening. You should also break up any large
chunks and distribute the coals so that the new wood is
laid evenly on hot coals.
480-1091
Fireplace operation does require air. Do not take air
from other fuel burning appliances which can result in
improper venting (smoking) or air dilution. Always provide
adequate makeup air.

4. Air Control

The air enters at the upper front of the firebox, near
the top of the glass door. This preheated air supplies
the necessary fresh oxygen to mix with the unburned
gases. This air is regulated by the Slide Air Control.
For more air - slide the control to the right, for less air
- slide the control to the left.
5. Automatic Combustion Control
ypically, when you build a fire, you need to open
T
the controls to give the fire more air so the wood will
get going. You then have to go back to the unit and
shut it down so it doesn't overfire and burn up your
wood too quickly.
With the Automatic Combustion Control system, you
can set the fireplace to high (all the way to the right),
start your fire, and then move the Slide Air Control to
their desired burn level. The fireplace will automatically
go to that level after the fire is fully established. This
allows for less interaction with the fire by the homeowner
and more efficient use of fuel while maintaining the
desired heat output.
IMPORTANT!
As you move the control rod to the
right, about three-fourths of the way you will feel
some resistance. You must move past that resistance
approximately 3/4" to fully engage the Automatic
Combustion Control (ACC) sytstem
Left-Close
Right-Open
Low
Position
22
CAUTION:
Slide Air Control
Outside Air Knob
OPEN
Meet
ACC Fully
Resistance
Engaged
CLOSE
4-03